4.3 Connection of Power Sources
LAW
Power source LAW is connected to terminal XP107 on the Control cabinet.
Control cable LAW
Figure 14 Control cable LAW
Signalbeskrivning/
Signal Denomination
Part/Core A B
42V AC 1 B A
Start PS 2 F B
Ref. 3 K C
0V 4 L D
Weld-/Weld Object 5 N F
Arc Voltage Gun 6 H G
Shield NC SH
PIB
Control cabinet
TB3
XP107
Power
source
B
A
XP107
LAW
503215A1
EXT. CABLE PS LAW
xxx xxx xxxx
Control cabinet