Operating instructions

Great Plains Manufacturing, Inc. Table of Contents Index Maintenance 43
2013-03-25 Table of Contents Index 403-362M
Air Release Tube
1 tube each wing end fertilizer delivery hose;
2 tubes per planter
Inspect. Clean any build-up on screen. Replace if
damaged. Re-install with opening facing down.
Note: Although depicted in exploded view, the tube is a
weldment and the screen cannot be removed.
Meter Box Door Seals
2 seals per planter
Inspect and replace if leaks are detected or appear
imminent.
Meter Flutes
1 flute shaft per planter,
2 sets of 2 stars (4 stars),
4 sets of 3 stars (12 stars);
16 stars total (each star is two halves)
Inspect from above with hopper empty. Shaft rotation is
required to expose all surfaces. Replace any broken or
visibly worn stars.
Seasonal
29723
Seasonal
31016
Seasonal
31016