Service manual

19
R-370EK
R-370ES
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
(5) Be sure the exterior of the cooking container and the interior of the oven are dry. Wipe off any moisture
with a dry cloth or paper towel.
(6) The Sensor works with food at normal storage temperature. For example, chicken pieces would be
at refrigerator temperature and canned soup at room temperature.
(7) Avoid using aerosol sprays or cleaning solvents near the oven while using Sensor settings. The
sensor will detect the vapor given of by the spray and turn off before food is properly cooked.
(8) If the sensor has not detected the vapor of the food, ERROR will appear and the oven will shut off.
Water load cooking test
WARNING : The oven should be fully assembled before following procedure.
Make sure the oven has been plugged in at least two minutes before checking sensor cook operation.
The cabinet should be installed and screws tightened.
(1) Fill approximately 200 milliliters (7.2 oz) of tap water in a 1000 milliliter measuring cup.
(2) Place the container on the center of tray in the oven cavity.
(3) Close the door.
(4) Touch the KITCHEN TIMER/CLOCK once, the POWER LEVEL pad twice, the START pad once, the
number pad 1 once and the number pad 4 once. Now, the oven is in the sensor cooking condition,
and "AH20", "SENSOR" and "COOK" will appear in the display.
(5) The oven will operate for the first 16 seconds, without generating microwave energy.
NOTE: ERROR will appear if the door is opened or STOP/CLEAR pad is touched during first stage of
sensor cooking.
(6) After approximately 16 seconds, microwave energy is produced.
If ERROR is displayed or the oven does not turn off, replace the AH sensor or check the control unit, refer
to explanation below. If the oven stops after 5 minutes and ERROR is displayed, the AH sensor is normal.
Check other parts except the AH sensor.
TESTING METHOD FOR AH SENSOR AND/OR CONTROL UNIT
To determine if the sensor is defective, the simplest method is to replace it with a new replacement
sensor.
(1) Disconnect the power supply cord, and then remove outer case.
(2) Open the door and block it open.
(3) Discharge high voltage capacitor.
(4) Remove the AH sensor.
(5) Install the new AH sensor.
(6) Reconnect all leads removed from components during testing.
(7) Re-install the outer case (cabinet).
(8) Reconnect the power supply cord after the outer case is installed.
(9) Reconnect the oven to the power supply and check the sensor cook operation as follows:
9-1. Fill approximately 200 milliliters (7.2 oz) of tap water in a 1000 milliliter measuring cup.
9-2. Place the container on the center of tray in the oven cavity.
9-3. Close the door.
9-4. Touch the KITCHEN TIMER/CLOCK pad once, the POWER LEVEL pad twice, the START pad
once, the number pad 1 once and the number pad 4 once.
9-5. The control panel is in automatic Sensor operation.
9-6. The oven turns off automatically, and the time for detecting moisture will be displayed.
If new sensor dose not operate properly, the problem is with the control unit, and refer to explanation
below.
CHECKING CONTROL UNIT
(1) Disconnect the power supply cord, and then remove outer case.
(2) Open the door and block it open.
(3) Discharge high voltage capacitor.
(4) Disconnect the sensor connector that is mounted to control panel.
(5) Then connect the dummy resistor circuit (see fig.) to the sensor connector of control panel.
(6) Disconnect the leads to the primary of the power transformer.
(7) Ensure that these leads remain isolated from other components and oven chassis by using insulation
tape.