PUMP MODULE / PLUMBING SPECIFICATIONS
PUMP MODULE COMPARTMENT
There shall be an enclosed compartment located above the pump module. The compartment shall be transverse to the
pump module and include hinged doors with access from both sides to store long handled tools and equipment. The
compartment sides shall be fabricated from smooth plate aluminum painted body color. The compartment top shall be
fabricated from NFPA tread plate material to form a walking surface on the top exterior of the compartment.
PUMP MODULE DUNNAGE AREA
There shall be an open dunnage area located directly above the pump panel compartment. The Dunnage area shall
extend upward from the pump panel compartment approximately 10.50” and be used to store miscellaneous Loveland
Fire & Rescue supplied equipment. The dunnage area sides shall be constructed of smooth plate aluminum painted body
color.
PUMP OPERATORS PANEL
Pump operators panel shall consist of all gauges, valve controls and switches needed for the efficient operations of the
pumping and auxiliary operations. Adequate LED lighting for night operations shall be provided. Final design of the pump
operator's panel shall be approved by the owner prior to construction. The pump operators panel shall be painted with a
black powder coat finish.
All outlets are to be controlled from operator’s panel. Each discharge outlet shall have a screw type drain valve of 3/4"
diameter, or quarter-turn ball type valves, to permit draining hose lines. Pump to have one central drain to completely
drain pump and all water lines. Pump shift to be a remote control type from inside cab and shall have manual override at
pump operator's panel. All connections must have proper clearance for the use of spanner wrenches. All inlets and outlets
to be capped with chrome plated caps and chains provided. The protective one-piece panel around all inlets and outlets
shall be smooth plate aluminum, bolted in place and removable with easy access for drain valves.
An air horn activation button shall be provided on the pump panel near the pressure governor. Below the button provide a
label with the wording “Evacuation Signal”
NOTE: The speedometer and odometer shall be deactivated while in pumping mode.
FIRE PUMP SPECIFICATIONS
1500 GPM FIRE PUMP
A Waterous Model CMUC20C fire pump shall be midship mounted with rating of 1,500 GPM @ 150 PSI. The pump must
be tested by the pump manufacturer for 10 minutes hydrostatically at a pressure of 500 psig. Certification by the pump
manufacturer must be provided.
TWO STAGE FIRE PUMP
The pump shall be a two stage centrifugal class "A" rated fire pump, designed specifically for the fire service