Specifications
Loveland Fire/Rescue
Pumper
Production Specification
SVI #769 Page 113 of 125 June 17, 2010
..\4) Pricing & Change Orders\Production Change Order.pdf
TANK FILL
There shall be one (1) tank fill discharge.
The discharge shall include:
One (1) Akron Brass 8000 series, 2" valve(s)
- Valve(s) shall be controlled with a push/pull type chromed "T" handle with adjustable linkage connected to the
valve. The control handle shall be located adjacent to the plumbing connection.
CURBSIDE PUMP MODULE DISCHARGE(S)
There shall be two (2) 2½” gated discharge(s) located in this area. Each discharge shall terminate with a 2½” NSTF x 2½”
NSTM chrome 30 degree down sweep elbow with a 2½” NSTF x 1½” NSTM chrome reducer and cap.
Each discharge shall include:
Two (2) Akron Brass 8000 series, 2½” valve(s)
- Valve(s) shall be controlled with a push/pull type chromed "T" handle with adjustable linkage connected to the
valve. The control handle shall be located adjacent to the plumbing connection.
Two (2) Innovative Controls model 3003000, ¾” brass 90 degree ball type drain valve with lift handle fitting and
color coded labels shall be provided for the above plumbing item. The valve shall be able to manually open the
drain valve when the line is under pressure and will be located on pump panel and plumbed to drain the lowest
point in the plumbing.
Two (2) Class 1 2½” liquid filled gauge(s)
- This gauge(s) shall have a white background with black text.
- The above gauge shall have a range from 0 to 400 psi.