Specifications
Loveland Fire/Rescue
Pumper
Production Specification
SVI #769 Page 118 of 125 June 17, 2010
..\4) Pricing & Change Orders\Production Change Order.pdf
RIGHT SIDE RUNNING BOARD - SIDE MOUNT PANEL
The right side mount pump panel shall be equipped with side running board. The running board will extend along the
width of the pump enclosure from the forward end of the body module to behind the chassis cab.
The running board shall be constructed of aluminum tread plate, bolted in place with stainless steel fasteners. The step
surfaces shall be in compliance to applicable sections of NFPA requirements.
RIGHT SIDE RUNNING BOARD – HOSE WELL
The running board shall contain a hose well designed to carry a minimum of 50’ of 5” soft suction hose with hold down
provisions.
PUMP ENCLOSURE ACCESS DOOR - LEFT SIDE UPPER
A vertically hinged pump panel access door shall be provided on the upper left side of the side mount pump enclosure.
The access door shall be hinged toward the front of the module and be approximately 18" high and as wide as possible.
The door shall be constructed of smooth plate aluminum powder coated black with push button type latches.
PUMP ENCLOSURE ACCESS DOOR - RIGHT SIDE UPPER
A vertically hinged pump panel access door shall be provided on the upper right side of the side mount pump enclosure.
The access door shall be hinged toward the front of the module and be approximately 18" high and as wide as possible.
The door shall be constructed of smooth plate aluminum powder coated black with thumb screw type fasteners.
PUMP PANEL - SIDE MOUNT
The pump operator's panel, along with the lower left hand and right hand pump panels shall be constructed of smooth
plate aluminum powder coated black and be fastened to the pump enclosure with 1/4" stainless steel bolts.
The instrument area shall have a stainless steel continuous hinge that shall swing towards the front of the module for easy
access to gauges.
LEFT SIDE PUMP PANEL - BOLTED
The pump panel installed on the left hand side of the pump enclosure shall be fastened to the pump enclosure with 1/4"
stainless steel bolts and nutserts.
RIGHT SIDE PUMP PANEL - BOLTED
The pump panel installed on the right hand side of the pump enclosure shall be fastened to the pump enclosure with 1/4"
stainless steel bolts and nutserts.
LABELS
Safety, information, data, and instruction labels for apparatus shall be provided and installed at the operator's instrument
panel.
The labels shall include rated capacities, pressure ratings, and engine speeds as determined by the certification tests.
The no-load governed speed of the engine, as stated by the engine manufacturer, shall also be included.
The labels shall be provided with all information and be attached to the apparatus prior to delivery.