Specifications

Loveland Fire/Rescue
Pumper
Production Specification
SVI #769 Page 122 of 125 June 17, 2010
..\4) Pricing & Change Orders\Production Change Order.pdf
FOAM TANK LEVEL GAUGE
One (1) Fire Research TankVision model WLA260-B00 tank remote indicator shall be installed. The indicator shall show
the volume of Class A foam concentrate in the tank on nine (9) easy to see super bright LEDs. A wide view lens over the
LEDs shall provide for a viewing angle of 180 degrees. The indicator case shall be waterproof, manufactured of
aluminum, and have a distinctive green label.
The remote indicator shall receive input information over a datalink from a Fire Research TankVision model WLA260-A00
tank primary indicator. It shall mirror the primary indicator. A 10' cable shall be provided to connect the datalink. The
remote indicator shall have the same program as the primary so that the two indicators are interchangeable.
HOSE BED STORAGE AREA
Hose bed storage area shall be located over water tank and body, and shall exit at the rear of the apparatus. The interior
of storage area shall be free from all projections such as nuts, sharp angles, or brackets that may damage equipment.
Length of hose bed shall be approximately 96” deep. The bottom of hose bed shall be no more than 68" above road
surface. All pre-connected hose line discharges shall be accessible just below the hose bed on the rear of the apparatus.
Hose bed shall be laid out as follows;
Far Left Side: 200” of 1 ¾” Pre-Connect
Left Side: 300’ of 2” Pre-Connect
Left Center/Center: 1000’ of 5” LDH Dead Load
Right Center: 400’ of 2 ½” Dead loaded
Right Side: 250’ of 3” Pre-Connect with 100’ of 2” to lay on top for alley line.
Right Side: Backboard storage
Far Right: 300’ of 3” Pre-connect, with space available for mounting a Blitz Fire Monitor
Additional hose storage will be as follows:
Front Bumper: 200’ of 1 ¾” in a flat or triple flat load
Booster line reel: 200’ of 1” hose will be mounted above the pump panel on the driver’s side
Right Side Pump: 50’ of 5” soft suction hose
ALUMINUM HOSE BED DECKING
The hose bed deck shall be constructed from 3" x 3/4" hollow aluminum extrusions welded into a one-piece grid to allow
ventilation and water drainage. The extrusions shall have an anodized radiused ribbed top surface. The deck will be
completely removable for easy access to the booster tank. The booster tank fill tower shall be protected as necessary to
prevent damage from equipment located in the storage area.
HOSE BED LIGHTS
Four (4) OnScene Solutions 9" LED Night Stik lights provided to illuminate the upper body walkway area. The lights shall
be activated when the hose bed doors are opened.
Each light shall be mounted in a polished cast aluminum housing to protect against damage from personnel or equipment.