Specifications

Loveland Fire/Rescue
Pumper
Production Specification
SVI #769 Page 47 of 125 June 17, 2010
..\4) Pricing & Change Orders\Production Change Order.pdf
GLASS TINT SIDE MID LH
The window located on the left hand side of the cab between the front and rear doors shall include a dark gray automotive
tint which shall allow forty-five percent (45%) light transmittance. The dark tint shall aid in cab cooling and help protect
passengers from radiant solar energy.
CLIMATE CONTROL
The cab shall include a 57,600 BTU @ 425 CFM front overhead heater/defroster which shall be provided and installed
above the windshield between the sun visors.
The cab shall also include a combination heater air-conditioning unit mounted on the engine tunnel. This unit shall offer
eight (8) adjustable louvers, (4 forward facing , four rearward facing) a temperature control valve and two (2) blowers
offering three (3) speeds which shall be capable of circulating 550 cubic feet of air per minute. The unit shall be rated for
36,000 BTU of cooling and 45,000 BTU of heating. The temperature and blower controls shall be located on the heater/air
conditioning unit.
All defrost/heating systems shall be plumbed with one (1) seasonal shut-off valve at the front corner on the right side of
the cab.
The air conditioner lines shall be a mixture of custom bent zinc coated steel fittings and Aero-quip GH 134 flexible hose
with Aero-Quip EZ-Clip fittings.
CLIMATE CONTROL ACTIVATION
The front overhead heater/defroster controls shall be located on the unit. The controls for the combination heater/air
conditioning unit shall be located on the Vista display and control screen.
A/C CONDENSER LOCATION
A roof mounted A/C condenser shall be installed centered on cab forward of raised roof against the slope rise.
A/C COMPRESSOR
The air-conditioning compressor shall be a belt driven, engine mounted, open type compressor that shall be capable of
producing a minimum of 13000 BTU at 1500 engine RPMs. The compressor shall utilize R-134A refrigerant and PAG oil.
CAB CIRCULATION FANS FRONT
The cab shall include two (2) all metal 6.00 inch air circulation fans installed in the outer front cab corners. Each fan shall
be controlled by an individual virtual button on the Vista control panel. The fans can be used to help defog the windshield
or to increase air circulation for passenger comfort.
CAB INSULATION
The cab ceiling and walls shall include 1.00 inch thick foam insulation. The insulation shall act as a barrier absorbing
noise as well as assisting in sustaining the desired climate within the cab interior.