Specifications
Loveland Fire/Rescue
Pumper
Production Specification
SVI #769 Page 87 of 125 June 17, 2010
..\4) Pricing & Change Orders\Production Change Order.pdf
REAR COMPARTMENT - CENTER (RC1)
The rear center compartment shall be transverse to both side rear compartments.
The rear center compartment shall start at the bottom of the body and extend up to bottom of hose bed, and extend as
deep as possible up to fuel tank allowing for body mounts.
The interior useable compartment width shall be approximately 41.0" wide.
The compartment door opening shall be approximately 34.0" wide.
This compartment shall have a ROM roll-up door.
The roll-up door slats and the door trim components shall be painted to match the single tone exterior
color.
The ROM door shall be equipped with a magnetic type door ajar switch integrated in lift bar handle and the lower
retainer block to signal open door.
There shall be NO keyed lock on this roll-up compartment door.
One (1) aluminum drip pan/door finish guard shall be provided with the rollup door.
A compartment threshold protection plate shall be installed on the bottom edge of the compartment door opening. The
threshold protection shall be fabricated from an aluminum extrusion with an anodized exterior finish.
COMPARTMENT COMPONENTS
There shall be vertically mounted aluminum shelf trac for shelving installation.
There shall be one (1) 400 lbs. slide-out tray(s) approximately 28" deep and as wide as the compartment layout or
door opening permits. The tray top shall be fabricated from 3/16" (.188) aluminum 3003H-14 alloy smooth plate
with a 3" vertical lip and welded corners to form a box type tray surface. The sliding tracks shall extend 100% of
the slide length. The tray assembly shall utilize a pneumatic cylinder mounted on underside to hold the tray in
both the extended and closed positions
- Reflective Scotchcal stripe shall be provided on the front face of the tray. The stripe shall be blue in color.
Two (2) vertically mounted OnScene Solutions LED Nightstiks.