COMPARTMENT LIGHTING
Each enclosed equipment compartment greater than 4 ft3 (0.1 m3) in volume and having an opening greater than 144 in.2
(92,900 mm2) shall have sufficient compartment lighting to provide a minimum of 2 fc (20 lx) at any location on the floor of
the compartment without any shelves, dividers, or equipment in the compartment.
Compartments such as ladder tunnels, pike pole storage tubes, or underbody compartments designed around the
volumetric requirements of specific equipment that can be removed without the use of article illumination shall not be
required to have compartment lighting.
All compartments shall be equipped with OnScene Nightstik LED lights with the following minimum light requirements;
Full Height Compartments, 63” Section (42 LED's)
Wheel well Compartments, 36” Section (24 LED's)
Rear Rescue Compartment, 63” Section (42 LED's)
Low Compartments, 18" Section (12 LED's), Vertical
Low Compartments, 36" Section (24 LED's), Horizontal
The OnScene Nightstik lights shall be rated at 100,000 hours of service and shall be provided with a 5 year free
replacement warranty.
STEP / GROUND LIGHTS
Step and ground lights shall be OnScene Solutions 9" LED Nightstik and be placed at any entry door and step where
personnel climb on or descend from the apparatus to ground level. OnScene LED lights shall have 6 LED lights per 9”
light, and shall be rated at 100,000 hours of service. On Scene Solutions LED lights shall be have a 5 year free
replacement warranty.
All of the required step and ground lights shall be activated when the parking brake is set.
LOW VOLTAGE ELECTRICAL SYSTEM- 12 VDC
General
Any low voltage electrical systems or warning devices installed on the fire apparatus shall be appropriate for the mounting
location and intended electrical load.
Where wire passes through sheet metal, grommets shall be used to protect wire and wire looms. Electrical connections
shall be with double crimp water-tight heat shrink connectors.
All 12 VDC wiring running from front to back of vehicle body shall be run in full length electrical wiring raceway down each
side of body.
Wiring
All electrical circuit feeder wiring supplied and installed by the fire apparatus manufacturer shall meet the requirements of
NFPA Chapter 13.
The circuit feeder wire shall be stranded copper or copper alloy conductors of a gauge rated to carry 125 % of the
maximum current for which the circuit is protected. Voltage drops in all wiring from the power source to the using device
shall not exceed 10 %. The use of star washers for circuit ground connections shall not be permitted.