Technical information
WIRE & CABLE
NETWORK
C
ABLE
COAX CABLE
& CONN.
MULTI-
CONDUCTOR
AUDIO CABLES
HEAT SHRINK
TUBING
ROUTING/
BUNDLING
MATERIALS
CABLE TIES/
T
APES
TERMINALS
MOISTURE-
RESISTANT
CONN.
LUGS & BOOTS
I.D. PRODUCTS
& LABELERS
TOOLS
BREAKERS
& FUSES
TERMINAL
BLOCKS
& B
US BARS
SWITCHES
SOLENOIDS
ACR’S
LIGHTS
& METERS
ENCLOSURES
PACER GROUP SARASOTA
CORPORATE HEADQUARTERS
NA
TIONAL AND OEM SALES
18004249549 • FAX: 9413799015
PACER GROUP FT. LAUDERDALE
EAST COAST SALES AND
AFTER
MARKET SALES
18006345031 • FAX: 9547638062
17www.pacergroup.net
Group
MULTICONDUCTOR CABLES
Pacer stocks a large variety of cables ranging from 16 gauge to 22 gauge, with the number of
individual conductors varying from 2 to as many as 25. These cables are used for control purposes
such as remote signaling as well as communications and broadcast applications. Our multi-conductor
cables are insulated with PVC (polyvinyl chloride). Conductors are tinned for excellent corrosion
resistance. These cables are manufactured to meet the latest UL, CSA and NEC requirements. Because
temperatures and voltages may not be the same from cable to cable, call for specifications on the
item you require. See Round Boat Cables for multi-conductor cables 16 AWG and larger with 2, 3 or 4 conductor configurations. Page 4.
FEATURES:
• Finely stranded tinned copper conductors
• Color coded PVC conductors
• Gray PVC jacket
• Temperature Range -20˚C to 80˚C (some cables may vary, call for specific information)
• Voltage Rating: 300V
• Resistant To: Acid, Alkalis, Abrasion, Ozone, Flame
COMPLIANCES:
NEC Article 800 Type CM (UL: 75˚C)
UL St
yle 2464 (UL: 80˚C, 300V)
CSA PCC (CSA: 80˚C)
Passes UL 70,000 Btu Vertical Tray Flame Test
Passes CSA FT4 Flame Test
*Power-Limited Tray Cable, NEC Type PLTC, 105˚C
**Capacitance Between Conductors
M22/2* 2 7/30 25.5 .013 .037 .190
M22/4 4 7/30 25.5 .010 .032 .190
M22/6 6 7/30 25.5 .010 .032 .219
M22/8 8 7/30 25.5 .010 .032 .235
M22/10 10 7/30 25.5 .010 .032 .269
M22/25 25 7/30 25.5 .010 .032 .369
M20/2* 2 7/28 28.0 .013 .037 .207
M20/3* 3 7/28 28.0 .013 .037 .217
M20/4 4 7/28 26.0 .016 .032 .236
M20/5 5 7/28 26.0 .016 .032 .254
M20/7 7 7/28 26.0 .016 .032 .275
M20/9 9 7/28 26.0 .016 .032 .317
M20/12 12 7/28 26.0 .016 .032 .354
M20/15 15 7/28 26.0 .016 .032 .393
M18/2* 2 16/30 30.0 .013 .037 .227
M18/3* 3 16/30 30.0 .013 .037 .238
M18/4* 4 16/30 30.0 .013 .037 .257
M18/5 5 16/30 28.0 .016 .032 .280
M18/9 9 16/30 28.0 .016 .032 .358
M18/15 15 16/30 28.0 .016 .032 .445
M16/2* 2 19/.0117 .34 .013 .037 .238
M16/3* 3 19/.0117 .34 .013 .037 .250
M16/4 4 19/.0117 .28 .021 .032 .306
M16/5 5 19/.0117 28.0 .021 .032 .334
M16/7 7 19/.0117 28.0 .021 .032 .364
M16/8 8 19/.0117 28.0 .021 .032 .395
M16/9 9 19/.0117 28.0 .021 .032 .425
M16/12 12 19/.0117 28.0 .021 .032 .479
M16/15 15 19/.0117 28.0 .021 .032 .530
M16/25 25 19/.0117 28.0 .021 .032 .657
ORDERING INFORMATION: Cut as required.
FLAT BRAID
Flat braided cable is a tight weave of soft drawn tinned copper wire. Originally constructed tubular,
it is rolled flat creating a specific width. Excellent for use in shielding short runs and is easily
terminated. Also, flat braid is ideal for use as a low impedance ground path. The flexibility gained
from the woven construction and the tinned copper conductors gives this material superb
durability against harsh marine conditions.
PART BRAID CONSTRUCTION APPROX. APPROX. CURRENT
NUMBER AWG CARRIERS # OF ENDS AWG EQUIV. CAPACITY AMPS*
M.5FB 36 48 384 10 53
M.75FB 36 48 816 7 85
M1FB 36 48 816 7 85
M1.5FB 30 48 528 3 150
ORDERING INFORMATION: Cut as required.
*Capacities shown are for bare cable in free air at 30C (86F). These values are intended as
a reference guide only.
PART
NUMBER
# OF
COND.
COND.
STRAND
NOMINAL
INSULATION
THICKNESS
NOMINAL
JACKET
THICKNESS
NOMINAL
O.D.
NOMINAL**
CC
CAPACITANCE
PF/FT