3.6 Functional test using LPKF
BoardMaster
Caution
Make sure that no other persons are working on the machine while the first
functional test is taking place.
First check the configuration of the serial port:
9600 baud , 8 data bits, 1 stop bit, no parity bit, hardware handshake and FIFO off
.
Also check that the correct interface has been selected in BoardMaster under
C
ONFIGURATION
, C
ONNECT
... .
Consult the BoardMaster manual if you require assistance.
The port in the field marked
(4)
in the screen-shot below is visible. This display indicates the
port the control data is being sent to. A NULL here indicates that the data is not being sent to
any port.
(1) (2)
(4) (3)
The remainder of the procedure is carried out using BoardMaster:
1.
Move the head manually using the cursor keys on the BoardMaster toolbar (3).
2.
Turn on the motor (1) (The motor runs at low speed during the
warm-up phase)
3.
Wait for the warm-up phase to complete.
4.
Lower/raise the head (2).
5.
Switch off the motor (1).
6.
Check the interface configuration, the connection cable and the PC interface if the
machine does not move.
Please note:
The motor cannot be switched on when the machine is in the tool change
position.