7.10 Removing the electronics unit
The control unit must be isolated from the mechanism.
First move the plotter head to the
TOOL CHANGE
position if the circuit board plotter is still
attached.
Now use the traverse buttons to move the crossbar to the centre of the machine base plate.
The head must not be in either the
TOOL CHANGE
or H
OME
position and the limit switches
must have been cleared.
Switch off the circuit board plotter and disconnect the device from the mains by removing the
mains connector.
Position of the screws for removing the electronics unit from the
LPKF ProtoMat 95s/II mechanism
Undo the electric connections between the mechanism and the control unit.
Tilt the circuit board plotter towards the head.
Undo feet 1, 2, 3, 4 and the Allen screws 5, 6 on the underside of the machine.
Remove the cover with the limit switches.
The control unit has now been released.
Caution
Check that the machine is disconnected from the mains by removing the
mains connector.