Specifications

Setup
34 ProtoMat 95s/II
5.6 Functional test using LPKF BoardMaster
Caution! Make sure that no other persons are working on the
machine while the first functional test is taking place.
› First check the configuration of the serial port:
9600 baud , 8 data bits, 1 stop bit, no parity bit, hardware
handshake and FIFO off.
› Also check that the correct interface has been selected in
BoardMaster
under
CONFIGURATION, CONNECT...
.
› Consult the
BoardMaster
manual if you require assistance.
The port in the field marked (
4
) in the screen-shot below is visible. This
display indicates the port the control data is being sent to. A NULL here
indicates that the data is not being sent to any port.
fig. 20:
The remainder of the procedure is carried out using
BoardMaster
:
1.
Move the head manually using the cursor keys on the
BoardMaster
toolbar (3).
2.
Turn on the motor (1) (The motor runs at low speed during the
warm-up phase)
3.
Wait for the warm-up phase to complete.
4.
Lower/raise the head (2).
5.
Switch off the motor (1).
6.
Check the interface configuration, the connection cable and the PC
interface if the machine does not move.
Note: The motor cannot be switched on when the machine is in the
tool change position.