Specifications

Maxiva UAX
October 17, 2013
529
8882693004 WARNING:Disconnectprimarypower priortoservicing.
Copyright©2013,HarrisBroadcast
Figure 5-17 FWD cable to REV port with 20dB pad
Note
The RFLD Sample cable is removed, and the FWD sample cable is connected to the REV input through a
20dB attenuator pad.
If an attenuator pad was originally present on the REV input, it should also be
moved along with the REV sample cable)
IfanattenuatorpadwasoriginallypresentontheFWDinput,shouldbemov ed alongwiththeFWDsamplecabletothe
REVinput.The20dBattenuatorpadcalledoutinthisprocedurewouldbeinadditiontoanyattenuatorpadalready
presentontheFWD samplecable.
Note
REV (reverse) and RFLD (reflected) are used here synonymously.
STEP 14 HighPointCalibration:Removethe20dBattenuatorpadusedintheprevious
stepandconnecttheFWDsamplecabledirectlytotheREVinput.PressSave
tostorethevalue.RefertoFigure518onpage530.