WARNING:Disconnectprimarypower priortoservicing. 8882693004
STEP 10 PressLPUOFFbutton.
STEP 11 OnthefrontscreenselectSETUP>SYSTEMSETTINGS>MODELNO.andthen
usetheupordownarrowstochangethemodelno.tothepreviousvalue.
STEP 12 Removecouplerandsettransmitterbacktonormaloperatingcondition.
STEP 13 Endofprocedure.
5.6.6 CalibratingPABPower
PABpowerlevelscanbefoundintheLPULCDbynavigatingtoSTATUS>PAB#>FWDPWRorREFPWR.Theselevels
canalsobeseenonthewebbrowserbynavigatingtotheEXCITERHOME>XMT RHOME>POWERAMPSscreen.If
thePABpowerlevelsdisplayeddono
tagreewiththemeasuredlevels,thencalibrationisneeded.
Caution
PAB POWER METERS ARE CALIBRATED AT TIME OF FACTORY FINAL TEST.
DO NOT ALTER POWER METER CALIBRATIONS UNLESS POWER
READINGS ARE CLEARLY IN ERROR. CONSULT FACTORY TEST DATA
SHIPPED WITH TRANSMITTER, PAYING PARTICULAR ATTENTION TO
EXCITER GAIN SETTINGS AND PA MODULE CURRENTS, TO DETERMINE IF
METERING MIS-CALIBRATION IS A POSSIBILITY TO BE INVESTIGATED.
STEP 1 ConnectacalibratedcouplertothePABoutputandconnecta625wattload
(minimumsizefora500WPAB)tothecoupleroutput.Thisproceduremust
beusedtocalibrateeachpoweramplifierblockinthesystem.
STEP 2 OnfrontscreenselectSETUP>XMTRPOWERSETTINGS>POWER
CALIBRATION.
STEP 3 UsetheUPcursorkeytoselectPA1REFLECTED,PA2REFLECTED,etc.
STEP 4 Withthecouplerinthesystem(asabove)measurethepowerattheforward
couplerport(don’tusemeteroffsetforthis).Theactualpoweroutofthe
couplerwillbeusedasareference.
STEP 5 Forthefirstpowerlevelrequestedinthereflectedcalibrationroutineyou
willturnupPABpoweroutputuntila‐16.5dBmpowerlevelatthecoupler
portisachievedfora500WPAB.Fora250WPABthelevelshouldbe‐
22.5dBm
STEP 6 Whenthe‐16.5or‐22.5dBmlevelisachieveddisconnectthepowermeter
andconnectashortSMAcablefromthecouplerporttotheREFIN
connectoronthebackofthePABbeingcalibrated.
STEP 7 PressSA VE.Thiswillmovethecalibrationroutinetothenextstepandask
youforanewdBmlevel.
STEP 8 Connectthepowermetertotheforwardcouplerportandthistimeincrease
theoutputpoweruntilyouread+3.5dBmonthemeterfora500WPABor‐
2.5dBmfora250WPAB.Whenthatlevelisattaineddisconnectthepower
meterandconnectashortSMAcablefromthec
ouplerporttotheREFIN
connectoronthebackofthePABbeingcalibratedandthenpressSA VE.
STEP 9 RestorethePABtoitsinitialstate.
STEP 10 SelectCONTINUEtoexitthereflectedcalibrationprocedure.
STEP 11 Repeatsteps110forthenextPABtobecalibrated.
Note
An alternate to the PAB reflected power calibration is possible if a signal generator is available on site.
The generator can be connected directly to the REF IN connector on the PAB rear and simply apply (on
frequency) the two signal levels noted above to that port to calibrate the reflected levels. That simplifies
the reflected calibration procedure by eliminating the need for a directional coupler.
STEP 12 Proce dur ecomplete.