Specifications

Maxiva UAX
October 17, 2013
535
8882693004 WARNING:Disconnectprimarypower priortoservicing.
Copyright©2013,HarrisBroadcast
5.7.2 StoringPrecorrection
STEP 1 GototheRTAC‐StoredCorrectionSetsScreen,Figure519.
Figure 5-19 RTAC Stored Correction Sets Screen
STEP 2
Enteraname(uptosixteencharacters)forthedesiredset.
STEP 3 PresstheSAVEbuttontostorethecorrection.
Note
The correction which is currently applied will be stored. For example, if nonlinear correction has already
been stored in Set 1 and a new linear correction must be stored in Slot 1, the Nonlinear mode will again be
saved when the linear correction set is saved.
STEP 4 Endofprocedure.
5.8 TCUMaintenance
ThissectionisamaintenanceguidetotheTCU(TransmitterControlUnit),anoptionalunittypicallyfoundindual
drivesystems.
5.8.1 TCUMCMandPCM2SoftwareUploads
TCUMCMandPCM2softwareuploadsarediscussedin"3.5.7TCUSoftwareManagementScreens"onpage318.
5.8.2 TCUTouchScreenCalibration
TheTCUGUItouchscreenhasbeencalibratedatthefactory .Shouldrecalibrationbecomenecessary,thecalibration
screencanbeaccessedbyswitchingtheTCUtouchscreendisplayoffforfifteensecondsthenbackon.TheON/OFF
switchisshowninFigure525onpa
ge542.Oncethedisplayisswitchedbackon,watchthescreenclosely.After
approximately35sec
ondsalineoftextstating"Touchthescreentobegincalibration"willbedisplayed(briefly).
Oncethislineisdisplayed,theusermusttouchthescreen(within2seconds)tobeginthefivepresscalibration
process.
Note
It is very easy to accidentally touch the screen twice when entering a calibration point. Should this happen
the GUI touchscreen will not operate properly. Repeat the calibration process to correct the error.
SimplytouchthecenterofeachoffiveXsastheyaredisplayedonthetouchscreen.