Specifications

Maxiva UAX
October 17, 2013
555
8882693004 WARNING:Disconnectprimarypower priortoservicing.
Copyright©2013,HarrisBroadcast
Figure 5-42 Battery Backup (UPS) Location
Theopt
ionalbatterybackupkit9710051012Gincludes:
Qty4,3020803006,Screw,MachM30.5X6SEMS
Qty1,6600179000,PWA ,9.6VBatteryPack
Ins
tructions:
STEP 1
IfsystemcontainsdualLPUsmanualmodeandmaketheLPUthatwillhave
thebatterychangetheinactiveunit.
STEP 2 DisconnectACmains powerfromtheLPUchassis.
Warning
REMOVE ALL POWER TO THE LPU BEFORE PERFORMING THE FOLLOWING PRO-
CEDURE.
Caution
FOLLOW APPROPRIATE ESD (ELECTROSTATIC DISCHARGE)
PROCEDURES TO PREVENT DAMAGE TO SENSITIVE
ELECTRONIC COMPONENTS WHEN HANDLING CIRCUIT
BOARDS.
STEP 3 Iftheunitisnotmountedinarackproceedtostep4.Ifrackmountedthe
UAXLPUmustberemovedfromtherack.Removecablesfromthebackof
theLPUusinga5/16”(8mm)openendwrenchandasmallstraightslot
screwdriver.RemoveorlowertheLPUfr
ontpanelandthefourPhillips
screwsthatholdtheLPUintherack.SlidetheLPUoutoftherackandplace
itonasturdytableorbench.
STEP 4 RemovethefourPhi llipsscrewsonthetop,rearoftheLPUthatsecurethe
chassiscover.RemovethecoverbyslidingittowardtherearoftheLPUand
liftingitupward.
STEP 5 Besurethattheconnectoronthebackofthebatterybackupboardaligns
andseatsproperlyonthepowersupplyboardconnector.Thepowersupply
boardstandoffsarelocatedonthefrontleftsideoftheLPU.
Battery
Backup