Specifications

Maxiva UAX
October 17, 2013
63
8882693004 WARNING:Disconnectprimarypower priortoservicing.
Copyright©2013,HarrisBroadcast
Figure 6-2 PA LEDs - left No Faults - right Under Voltage Fault
Figure 6-1 PAB LEDs (Control, Fan, & VSWR Summary Faults Active)
6.3 WebBrowserFaultLog
Thewebbrowserallowsaccesstolistingsofanyfaultsorwarningsthathaveoccurred.TheTCUeventlogis
accessedbypressingtheEventLogsoftbuttonontherightsideoftheTCUHomescreen.TheLPUfaultlogis
accessedbypressingtheFaultLogsoftbuttonontherightsi
deoftheLPUExciterHomescreen.Thiswillbringup
theTCUEventLogscreenortheLPUFaultLog‐AllFaultsscreen.Theeventandfaultlogsgivethefollowing
information:
a. Order‐Therecanbeupto1,000faultsstoredintheTCUeventlog ,afterwhich,faultsaredeletedonaFIFO
(FirstInFirstOut)basis.TheTCUeventlogcanbeviewedinitsentirety,printed,orexportedbydouble
clickingonthewebbrowserscreeneventlisting.
TheLPUfa
ultlogstoresupto500entries,afterwhich,faultsaredeletedonaFIFObasis.Thelast
fiftyfaultscanbeviewedintheLPUfaultlog.Theentirefaultlogincludingolderfaultscanbe
viewedorexportedviathewebbrowserbynavigatingtotheLPUSta
tusscreenandpressing
ExportFltLog.