2.10 InitialStartupProcedure
ThefollowingprocedurepresentsthestepsrequiredtoturnonsafelytheUAXtransmitterforthefirsttime.Itis
recommendedthatinstallationpersonnelfullyreadthegeneralproductdescriptioninSection1,thecontrolsand
operationmaterialinSection3,andtheseproceduresbeforestarting.
STEP 1
Openallmainscircuitprotectiondevices(breakers,fuses)asasafety
precaution.
STEP 2 Carefullyinspectthetransmitterforanyloosehardware,unconnectedwires,
missingparts,debris,orothersignsofdamagefromshipmentor
installation.
STEP 3 Verifythatthefollowingbasicrequirementshavealreadybeenmet:
Achannel izedRFmaskfilter(ifrequiredandnotinstalledinthecabinetatthefactory)ofadequatepowerrat
ingisco
nnectedtothesystemRFoutput.
Atransmittingantennaordummyloadof50ohmsisconnectedtothesystemRFoutput(usuallytothemask
filter).
Allblowerexhaustandairinletopeningsarenotblocked,andallnecessaryductworkisinplace.
AllrackmountedunitshaveacontinualACmainssafetygroundconnectionviagreen/yellowconductor(third
prong)backtothemainsafetygroundattheACserviceentrance.
AsuitableACmainsconnectionwithsurgeprotectiondeviceshasbeenmadeperthesystemdrawings.
ThetransmitterrackandallrackmountedunitshaveprotectiveRFearthgroundingasnecessary.
TheRFmuteandsafetyinterlockshavebeensatisfied(S eeSection2.9.4onpage28)
Asuitableprograminputsignal(video,ASI,ETI,SMPTE,etc)isconnectedtotheappropriatesocketsonrear
panelofLPUorcustomerI/Opanelatthetopoftherack(whereapplicable).(See2.9.5onpa
ge210)
Ifnecessary, asuitablefrequencycontrolsignal(10MHz,GPS,1pps)isconnectedtoappropriatesocketson
rearpanelofLPUorcustomerI/Opanelatthetopoftherack(whereapplicable).(See2.9.5onpa
ge210)
ThenecessaryRFsamplestoprovidesystemoutputmeteringandRTAChavebeeninstalled.(See2.9.6on
page212)
Thepropertestequipmentisonhandtoevaluatethetransmittedsignalqualityandprovideacalibrated
meanstoverifytheoutputpowerlevel.(e.g.spectrumanalyzer,waveformmonitor/signalanalyzer,average
powermeter)
Theoriginalfactorytestdatashippedwithtransmitterisonhandandreadyforconsultation.
STEP 4
InstalltheLPUandPABPAandPSmodules.Dependingonthetransmitter
model,thePAandPSmodulesmaybeshippedinstalledinthetransmitteror
removedandplacedinaseparateshippingcontainer.Refertothefactory
testdata.EachPAmodulehasaserialnumber.ThePAmodulewi
llworkin
anyPAslotlocationbutshouldbeinstalledinthesamepositionsinwhich
theyweretested.