R FU-Z31E *Plasmacluster is a trademark of Sharp Corporation. *Plasmacluster adalah Merek Dagang dari Sharp Corporation. PETUNJUK PENGOPERASIAN AIR PURIFIER INDONESIA ENGLISH AIR PURIFIER OPERATION MANUAL Free standing type Tipe Berdiri No. Reg. : 03/DJ-ILMEA/MG/I/2000 FU-Z31E.indd 1 10.4.
Please read before operating your new Air Purifier Some odour ingredients absorbed by the filter may become separated and may be discharged through the air outlet and result in additional odour. Depending on the usage environment, especially when the product is used in a condition significantly more severe than household use, this odour may become strong in a shorter period than expected. In this case we recommend purchasing the optional replacement filter.
ENGLISH *1 Graduate School of Advanced Sciences of Matter, Hiroshima University, Japan Measurement of action on the potential allergens of aerial mites in (13m²) *2 Retroscreen Virology, Ltd.
IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, basic safety precautions should be followed, including the following: WARNING - To reduce the risk of electrical shock, fire or injury to persons: • Read all instructions before using the unit. • Use only a 220-240 volt outlet. • Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loosened. • Periodically remove dust from the power plug.
CAUTIONS CONCERNING OPERATION INSTALLATION GUIDELINES • During the operation of the product, please place the unit at least 2 m away from equipment utilizing electrical waves such as televisions, radios or wave clocks. • Avoid locations where curtains, etc., come into contact with the intake or air outlet. Curtains, etc., may become dirty or a malfunction may occur. • Avoid locations where the unit is exposed to condensation, due to rapid temperature changes.
PART NAMES MAIN UNIT DISPLAY POWER ON/OFF Button Plasmacluster Ion ON/OFF Button MODE Button Odour Sensor Plasmacluster Ion ON/OFF Indicator Light Fan Speed Indicator Lights CLEAN SIGN The odour sensor continuosly monitors the air and changes colour depending on air punity. Green Orange Clean Red Very Impure ILLUSTRATIVE DIAGRAM Handle Main Unit E-4 FU-Z31E.indd 6 10.4.
INCLUDED • Operation manual BACK Handle Filter (Dust Collection / Deodorising Filter) ENGLISH Tab Air Outlet INDONESIA Date Label Back Panel Air Inlet Power Cord Plug (Shape of plug depends on country.) E-5 FU-Z31E.indd 7 10.4.
PREPARATION Be sure to remove the power plug from the wall outlet. FILTER INSTALLATION To maintain the quality of the filter, they are installed in the main unit and packed in plastic bag. Be sure to remove the filter from the plastic bag before using the unit. 1 Tab Remove the filter 1 Remove the Back Panel. Pull the tab at the top of the Back Panel. the Filter from the 2 Remove plastic bag. 2 Intall the filter 1 Place the Filter within the main unit.
2 Replace the Back Panel to the main unit. 3 Fill in the usage start date on the Date Label. INDONESIA ENGLISH Push until it clicks into place. Use the date as a guide for the filter replacement schedule. Date Label E-7 FU-Z31E.indd 9 10.4.
OPERATION MAIN UNIT OPERATION MODE Button Plasmacluster Ion ON/OFF Button Fan Speed Indicator Lights Plasmacluster Ion Indicator Light POWER ON/OFF Button Power ON/OFF Button • Press to start operation (short beep) and stop operation (long beep) • Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off. • Unless the power cord has been unplugged, the operations starts in the previous mode it was operated in. MODE Button • Press the MODE Button to select the desired fan speed.
CARE AND MAINTENANCE To maintain optimum performance of this air purifier, please clean the unit including the filter periodically. When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result. BACK PANEL and SENSORS Care Cycle Whenever dust accumulates on the unit or every 2 months 1 2 3 In case of heavy dirt, soak the back panel in water with a small amount of kitchen detergent. (Approx. 10min.
CARE AND MAINTENANCE FILTER REPLACEMENT GUIDELINES Filter life vary depending on the room environment, usage, and location of the unit. If dust or odour persists, replace the filter. (Refer to “Please read before operating your new Air Purifier”) Guide for filter replacement timing • The following filter life and replacement period is based on the condition of smoking 5 cigarettes per day and the dust collection/deodorization power is reduced by half compared with that of new filter.
TROUBLESHOOTING Before calling for service, please review the Troubleshooting chart below, since the problem may not be a unit malfunction. Odours and smoke are not removed. • Replace the filter if it appear to be heavily soiled. (See E-10) The Clean Sign illuminates green even when the air is impure. • The air could be impure at the time the unit was plugged in. Unplug the unit, wait one minute, and plug the unit in again. The Clean Sign illuminates orange or red even when the air is clean.
SPECIFICATIONS FU-Z31E 220-240V 50/60Hz Model Power supply Fan Speed Adjustment Rated Power Fan Speed Recommended Room Size High density Plasmacluster ion recommended room size Fan Speed Operation MAX 49W 180m3/hour MED 32W 120m3/hour LOW 23W 60m3/hour ~21m2 *1 ~13m2 *2 2.0m 356mm(W)x180mm(D)x510mm(H) 5.0kg Cord Length Dimensions Weight *1 Size of a room which is appropriate for operating the unit at maximum fan speed.
SHARP CORPORATION OSAKA, JAPAN Printed in China TINS-A420KKRZ FU-Z31E.indd 32 10C- CN 1 10.4.