ASSEMBLING PROCEDURES OF MAIN PARTS AND CAUTIONS
CAUTION: DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY REPAIRING.
1. R-AIR GUIDER ASSEMBLY
Figure A-1
After forming, fix it to the refrigerator.
Stick thermo.
cap. sealer
Less than 130 mm
Damper
thermostat
5
1
mm
8
1
mm
Less than 12 mm
10
2
mm
NOTE
Minimum bending radius is R5mm.
There should be no gas leak by reforming of sensor tube.
+
++
Figure A-2
(1) Forming sensor of Damper thermo.
Damper thermo.
Thermo. cap. seal
er
A-sealer ag3
A-sealer ag2
A-sealer ag1
Dial sealer
R air guider
(2) Sticking sealers to R air guider.
214mm
A-sealer
ag1
A-sealer
ag1
A-sealer
ag1
A-sealer
ag1
A-sealer
ag3
A-sealer
ag2
Dial sealer
R air guider
R air guider
R air guider
R air guider
DATUM
DATUM
OVERLAP
8mm
OVERLAP AREA
Figure A-3