Service manual

15
SJ-D30M
SJ-D33M
(5) Setting of F-thermostat
(5)-1 Form capillary tube of F-thermostat.
(5)-2 Insert terminal of Lead EV-cover ass'y.
Figure A-13
After inserting, fix with vinyl tape.
Figure A-11
1234
5678
F-thermostat 2
F-thermostat 6
(BROWN, inserted)
Fuse 8 (BLACK)
Fuse 8 (WHITE)
Fan motor 1 , 5
(RED, inserted)
Defrost thermo. 3 (PINK)
Defrost thermo. 7 (BLUE)
WIRE COLOR FOR FAN MOTOR
100-110V : WHITE
127V : YELLOW
220-240V : BLUE
Note Pins should be inserted surely,
and check by pulling it.
Figure A-12
Vinyl tape
Figure A-14
SEC. B B
B
B
F-thermostat
(4) Inserting of pins
15mm
7mm
30mm
Note
Bending radius of capillary
tube should be R5mm to R10mm.
7mm
15mm
35mm
10mm
BROWN
RED
(5)-3 Set to E.V cover.