Para obtener un ejemplar en Español de este Manual del propietario, visite www.heatnglo.com. Pour demander un exemplaire en français de ce Manuel du propriétaire, visitez www.heatnglo.com. Owner’s Manual Installation and Operation Models: SL-550TR-E SL-750TR-E SL-950TR-E SL-550TR-IPI-E SL-750TR-IPI-E SL-950TR-IPI-E NOTICE DO NOT DISCARD THIS MANUAL • Important operating and maintenance instructions included. • Read, understand and follow these instructions for safe installation and operation.
Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. A. Congratulations This owner’s manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals. Congratulations on selecting a Heat & Glo gas fireplace, an elegant and clean alternative to wood burning fireplaces.
Safety Alert Key: • • • • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE: Used to address practices not related to personal injury. Table of Contents A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13 Finishing A. B. C. D. E. Splatter Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Decorative Fronts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elevated Hearth Systems . . . . . . . . . . . . . . . . . . . . . . . . . 54 56 57 58 59 14 Appliance Setup A. B. C. D. E. F. G. H. I.
B. Limited Lifetime Warranty Hearth & Home Technologies LIMITED LIFETIME WARRANTY Hearth & Home Technologies, on behalf of its hearth brands (“HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.
B. Limited Lifetime Warranty (continued) WARRANTY CONDITIONS: • • • • • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites. This warranty is only valid while the HHT appliance remains at the site of original installation. This warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the appliance resides.
1 Listing and Code Approvals A. Appliance Certification C. BTU Specifications MODELS: SL-550TR-E, SL-750TR-E, SL-950TR-E LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Direct Vent Heater STANDARD: ANSI Z21.88-2014 • CSA 2.33-2014 This product is listed to ANSI standards for “Vented Gas Fireplace Heaters” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and Recreational Vehicles”, and “Gas Fired Appliances for Use at High Altitudes”.
Note: The following requirements reference various Massachusetts and national codes not contained in this document. H.
2 Operating Instructions User Guide A. Appliance Safety • Teach children to NEVER touch the fireplace. WARNING! DO NOT operate fireplace before reading and understanding operating instructions. Failure to operate fireplace according to operating instructions could cause fire or injury. • Consider not using the fireplace when children will be present. DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. • Keep children away.
C. Fan Kit (optional) F. Fixed Glass Assembly If desired, a fan kit may be added. Contact your dealer to order the correct fan kit. See Section 14.G. D. Clear Space WARNING! DO NOT place combustible objects in front of the fireplace or block louvers. High temperatures may start a fire. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects. G.
I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer. To prolong battery life, remove them when using the transformer. FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an intermittent pilot ignition (IPI) device which automatically lights the burner.
J. Lighting Instructions (Standing Pilot) FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. B.
K. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • Turn the fireplace off and allow it to completely cool. • Remove fixed glass assembly. See Section 14.G. • Clean fixed glass assembly. See Section 3. • Replace the fixed glass assembly and run continuously on high an additional 12 hours. This cures the materials used to manufacture the fireplace. NOTICE! Open windows for air circulation during fireplace break-in.
3 Maintenance and Service Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace. When properly maintained, your fireplace will give you many years of trouble-free service. We recommend annual service by a qualified service technician. A. Maintenance Tasks-Homeowner Installation and repair should be done by a qualified service technician only. The fireplace should be inspected before use and at least annually by a professional service person.
Tools needed: Protective gloves, drop cloth and a stable work surface. • Inspect gasket seal and its condition. • Inspect fixed glass assembly for scratches and nicks that can lead to breakage when exposed to heat. • Confirm there is no damage to glass or glass frame. Replace as necessary. • Verify that fixed glass assembly is properly retained and attachment components are intact and not damaged. Replace as necessary.
4 Installer Guide Getting Started A. Typical Appliance System NOTICE: Illustrations and photos reflect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual. HORIZONTAL TERMINATION CAP (SECTION 10.L) Note: Dual venting configurations ARE NOT allowed. Appliance MUST be vented EITHER ver tically OR horizontally. VERTICAL TERMINATION CAP (SECTION 10.
B. Design and Installation Considerations D. Inspect Appliance and Components Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required. • Carefully remove the appliance and components from the packaging. Installation MUST comply with local, regional, state and national codes and regulations.
5 Framing and Clearances A. Selecting Appliance Location NOTICE: Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference. When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.
B. Constructing the Appliance Chase firestops should be caulked with caulk with a minimum of 300ºF continuous exposure rating to seal gaps. Gas line holes and other openings should be caulked with caulk with a minimum of 300ºF continuous exposure rating or stuffed with unfaced insulation. If the appliance is being installed on a cement surface, a layer of plywood may be placed underneath to prevent conducting cold up into the room.
D. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clearances as specified. Framing or finishing material closer than the minimums listed must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc). 1/2 IN. MINIMUM CEILING All measurements are in inches. 2-7/8 IN. MINIMUM 3 FT. MAXIMUM 12 10 9 5 3 6 7 11 Note: Clearance from opening to perpendicular wall. 8 32 4 4 5 6 7 8 10 9 11 12 Figure 5.
6 Termination Locations A. Vent Termination Minimum Clearances WARNING A B 6 in. (minimum) up to 20 in. 152 mm/508 mm 18 in. minimum 457 mm 20 in. and over 0 in. minimum Fire Risk. Maintain vent clearance to combustibles as specified. • DO NOT pack air space with insulation or other materials. Failure to keep insulation or other materials away from vent pipe may cause overheating and fire. Gas, Wood or Fuel Oil Termination Cap B A* HORIZONTAL OVERHANG 2 FT. MIN. 20 INCHES MIN.
O N P R F C V Q B J H or i B V D V B V V H V X G M V A V E H V V V L A V V = VENT TERMINAL X = AIR SUPPLY INLET K B C V V = 12 inches.................clearances above grade, veranda, porch, deck or balcony = 12 inches.................clearance to window or door that may be opened, or to permanently closed window = 18 inches.................clearance below unventilated soffit 18 inches.................clearance below ventilated soffit 30 inches .................
7 Vent Information and Diagrams A. Approved Pipe DO NOT mix pipe, fittings or joining methods from different manufacturers. Vertical 12 in . The pipe is tested to be run inside an enclosed wall. There is no requirement for inspection openings at each joint within the wall. 8-1/2 in. WARNING! Risk of Fire or Asphyxiation. This appliance requires a separate vent. DO NOT vent to a pipe serving a separate solid fuel burning appliance. B.
E. Use of Flex Vent The flex vent must be supported with the spacing between support intervals not exceeding 4 feet, with no more than 1/2 inch sag between supports. A support is required at each change in venting direction, and in any location where it is necessary to maintain the necessary clearance to combustibles. A simple “up and out” installation (Figure 5.3) requires only enough support to maintain the necessary clearance to combustibles.
F. Vent Diagrams Top Vent - Horizontal Termination Venting with one 90º elbow V1 Minimum 90 Elbow * H1 Maximum SL-550TR-E SL-750TR-E SL-950TR-E 2 ft. 610 mm 2 ft. 610 mm 1 ft. 305 mm 152 mm 2 ft. 610 mm 2 ft. 610 mm 2 ft. 610 mm 1-1/2 ft.* 457 mm 3 ft. 914 mm 3 ft. 914 mm 3 ft. 914 mm 2-1/2 ft.* 762 mm 5 ft. 1.5 m 5 ft. 1.5 m 5 ft. 1.5 m 3-1/2 ft. 1.1 m 7 ft. 2.1 m 7 ft. 2.1 m 7 ft. 2.1 m 4-1/2 ft. 1.4 m 14 ft. 4.3 m 14 ft. 4.3 m 14 ft. 4.3 m 1/2 ft.
Top Vent - Horizontal Termination Venting with two 90º elbows V Minimum 90 Elbow * H1 + H2 Maximum SL-550TR-E SL-750TR-E 1/2 ft. 152 mm 1/2 ft. 152 mm SL-950TR-E 0 ft. 0 mm 1/2 ft.* 152 mm 1 ft. 305 mm 1 ft. 305 mm 1 ft. 305 mm 1-1/2 ft.* 457 mm 2 ft. 610 mm 2 ft. 610 mm 2 ft. 610 mm 2-1/2 ft.* 762 mm 4 ft. 1.2 m 4 ft. 1.2 m 4 ft. 1.2 m 3-1/2 ft. 1.1 m 6 ft. 1.8 m 6 ft. 1.8 m 6 ft. 1.8 m 4-1/2 ft. 1.4 m 14 ft. 4.3 m 14 ft. 4.3 m 14 ft. 4.
Top Vent - Horizontal Termination Venting with three 90º elbows V1 Minimum 90 Elbow ** H1 + H2 Maximum SL-550TR-E SL-750TR-E SL-950TR-E V2 V1 + V2 Min. 2 ft. 610 mm 2 ft. 610 mm 2 ft. 610 mm * * 6 ft. 1.8 m 6 ft. 1.8 m 6 ft. 1.8 m * * 1-1/2 ft.** 457 mm 10 ft. 3.0 m 10 ft. 3.0 m 10 ft. 3.0 m * * 2-1/2 ft.** 762 mm 12 ft. 3.7 m 12 ft. 3.7 m 12 ft. 3.7 m * * 4.3 m 14 ft. 4.3 m 14 ft. 4.3 m * * 1/2 ft.** 3-1/2 ft. 152 mm 1.1 m 14 ft.
Top Vent - Vertical Termination No Elbows V1 = 60 ft. Max. (18.3 m) Note: If installing a vertical vent/termination off the top of the appliance, the optional vertical termination baffle may be needed. Exhaust restrictor Instructions 1. Install the exhaust restrictor over the center of the exhaust outlet in the firebox (see Figure 7.8). 2. Center the exhaust restrictor in the open end of the exhaust outlet and secure through the slots on the exhaust restrictor with the 2-1/4 in.
Top Vent - Vertical Termination Venting with two 90º elbows V1 MIN. 90 Elbow SL-550TR-E SL-750TR-E SL-950TR-E H MAX. H MAX. H MAX. 1-1/2 ft. 457 mm 1-1/2 ft. 457 mm 1 ft. 305 mm V2 V1 + V2 MIN. * * 1/2 ft. 152 mm 2 ft. 610 mm 2 ft. 610 mm 2 ft. 610 mm * * 1-1/2 ft. 457 mm 3 ft. 914 mm 3 ft. 914 mm 3 ft. 914 mm * * 2-1/2 ft. 762 mm 5 ft. 1.5 m 5 ft. 1.5 m 5 ft. 1.5 m * * 3-1/2 ft. 1.1 m 7 ft. 2.1 m 7 ft. 2.1 m 7 ft. 2.1 m * * 4-1/2 ft. 1.4 m 15 ft.
Top Vent - Vertical Termination Venting with three 90º elbows V1 MIN. 90 Elbow SL-550TR-E SL-750TR-E SL-950TR-E H MAX. H MAX. H MAX. V2 V1 + V2 MIN. 1/2 ft. 152 mm 1/2 ft. 152 mm 0 ft. 0 mm * * 152 mm 1 ft. 305 mm 1 ft. 305 mm 1 ft. 305 mm * * 1-1/2 ft. 457 mm 2 ft. 610 mm 2 ft. 610 mm 2 ft. 610 mm * * 2-1/2 ft. 762 mm 4 ft. 1.2 m 4 ft. 1.2 m 4 ft. 1.2 m * * 3-1/2 ft. 1.1 m 6 ft. 1.8 m 6 ft. 1.8 m 6 ft. 1.8 m * * 4-1/2 ft. 1.4 m 14 ft. 4.3 m 14 ft.
Top Vent - Vertical Termination Venting with four 90º elbows V1 MIN. Note: Use SLP Series components only. 1-1/2 ft. H1 MAX. 457 mm 4 ft. 1.2 m V2 MIN. 4 ft. 1.2 m H2 MAX. 4 ft. 1.2 m V3 MIN. 3-1/2 ft. 1.0 m V1 + V2 + V3 + H1 + H2 Maximum= 40 ft. (12.2 m) Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 7.3). V3 V2 H2 H1 V1 Figure 7.11 Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev.
Rear Vent - Horizontal Termination No Elbows CAUTION *For SL-950TR-E ONLY: H1 Maximum can be up to 24 inches ONLY if the Optional Refractory Kit (BRICK-950-E) is NOT used. Note: Use DVP Series components only. H1 MAX SL-550TR-E 24 in. 610 mm SL-750TR-E 24 in. 610 mm SL-950TR-E 18 in.* 457 mm Figure 7.12 Rear Vent - Horizontal Termination One 45º Elbow H1 = 9 in. (229 mm) Maximum For corner installation of models SL-550TR-E and SL-750TR-E ONLY Note: Use DVP Series components only.
Rear Vent - Horizontal Termination Venting with two 90º elbows Note: Use DVP Series components only. H1 MAX. V1 MIN. H2 MAX. 1-1/2 ft. 457 mm Back to back elbows H1 + H2 MAX. 1 ft. 305 mm 2-1/2 ft. 762 mm 3 ft. 914 mm 1 ft. 305 mm 3 ft. 914 mm 6 ft. 1.8 m 5 ft. 1.5 m 3 ft. 914 mm 5 ft. 1.5 m 10 ft. 3.0 m 7 ft. 2.1 m 5 ft. 1.5 m 7 ft. 2.1 m 14 ft. 4.3 m H1 MAX. = 7 ft. (2.1 m) H1 + H2 MAX. = 14 ft. (4.3 m) V1 + H1 + H2 MAX. = 40 ft. (12.2 m) V1 H2 H1 Figure 7.
Rear Vent - Vertical Termination Venting with one 90º elbow Note: Use DVP Series components only. V1 MIN. H1 MAX. 1 ft. 305 mm 3-1/2 ft. 1.1 m 2 ft. 610 mm 5-1/2 ft. 1.7 m 3 ft. 914 mm 7-1/2 ft. 2.3 m H MAX. = 7-1/2 ft. (2.3 m) V1 + H1 MAX. = 40 ft. (12.2 m) V1 H1 Figure 7.16 Note: Use DVP Series components only. Rear Vent - Vertical Termination Venting with two 90º elbows H1 + H2 MAX V1 152 mm Back to back elbows 2-1/2 ft. 762 mm 1 ft. 305 mm 4-1/2 ft. 1.4 m 2 ft.
Rear Vent - Vertical Termination Venting with three 90º elbows V1 MIN. Back to back elbows H1 MAX. H2 MAX. H1 + H2 MAX. 1-1/2 ft. 457 mm 1 ft. 305 mm 2-1/2 ft. 762 mm 1 ft. 305 mm 3-1/2 ft. 1.1 m 3 ft. 914 mm 6-1/2 ft. 2.0 m 2 ft. 610 mm 5-1/2 ft. 1.7 m 5 ft. 1.5 m 10-1/2 ft. 3.2 m 3 ft. 914 mm 7-1/2 ft. 2.3 m 7 ft. 2.1 m 14-1/2 ft. 4.4 m H1 MAX. = 7-1/2 ft. (2.3 m) H1 + H2 MAX. = 14-1/2 ft. (4.4 m) V1 + V2 + H1 + H2 MAX. = 40 ft. (12.
Coaxial to Colinear Venting The coaxial to colinear adapter (DV-46DVA-GCL) is approved for installations into solid fuel masonry or factory built fireplaces that have been installed in accordance with the National, Provincial, State and local building codes. The DV-46DVA-GCL must be recessed into existing masonry fireplace. See Table 1 and Figure 7.20. OUTSIDE FACE OF FIREPLACE EXHAUST VENT PIPE TOP OF FIREPLACE OPENING 5 IN. MIN. INLET AIR VENT PIPE EXHAUST VENT PIPE 3 IN. MIN.
Connecting the DV-46DVA-GCL Adapter to Appliance Top Vent • Remove top seal cap and insulation if equipped. See Section 14, “Appliance Setup.” Attach the DV-46DVAGCL adapter to the appliance starting collar with 3-1/2 in. self-tapping screws. See Figure 7.21. Rear Vent • Remove the rear seal cap and insulation if equipped. Connect the DVP-2SL adapter to the vertically positioned elbow. Follow installation instructions included with DVP2SL kit. Secure DV-46DVA-GCL adapter to DVP-2SL with 3-1/2 in.
8 Vent Clearances and Framing A. Pipe Clearances to Combustibles B. Wall Penetration Framing WARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: Combustible Wall Penetration Whenever a combustible wall is penetrated, you must frame a hole for the wall shield firestop(s). The wall shield firestop maintains minimum clearances and prevents cold air infiltration.
C. Install the Ceiling Firestop A ceiling firestop MUST be used between floors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/fl oor (see Figure 8.3). ATTIC ABOVE • SLP pipe only - Frame opening 9 in. x 9 in. (229 mm x 229 mm) whenever the vent penetrates a ceiling/floor (see Figure 8.3). • Frame the area with the same sized lumber as used in ceiling/floor joist.
9 Appliance Preparation A. Top Vent CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp. Note: Actual unit may look different than the fireplace shown in this section. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. 2 SCREWS Figure 9.4 Remove the seal cap. Figure 9.1 For top vent, remove the two screws holding the top heat shield in place.
NOTICE: Once the seal cap has been removed it CANNOT be reattached. 2 SCREWS Figure 9.7 To attach the first section of vent pipe, make sure to use the fiberglass gasket to seal between the first vent component and the outer fireplace wrap. Use 2 selftapping screws to secure the gasket to the outer wrap. Figure 9.10 Fold the center parts of the retaining band out and use to remove the seal cap. Note: Once the vent cap has been removed, it cannot be reattached. B.
C. Securing and Leveling the Appliance WARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blownin insulation. Make sure insulation and other materials are secured. DO NOT notch the framing around the appliance standoffs. Failure to maintain air space clearance may cause overheating and fire.
10 Installing Vent Pipe (DVP and SLP Pipe) A. Assemble Vent Sections (DVP Pipe Only) Attach Vent to the Firebox Assembly Note: The end of the pipe sections with the lanced tabs will face toward the appliance. Attach the first pipe section to the starting collar: • Lanced pipe end to the starting collar • Inner pipe over inner collar • Push the pipe section until all lanced tabs snap in place • Lightly tug on pipe to confirm it has locked.
B. Assemble Vent Sections (SLP Pipe Only) C. Assemble Slip Sections To attach the first vent component to the starting collars of the appliance: • Slide the inner flue of the slip section into the inner flue of the pipe section and the outer flue of the slip section over the outer flue of the pipe section. See Figure 10.6. • Lock the vent components into place by sliding the pipe section onto the collar. • Slide together to the desired length.
D. Secure the Vent Sections E. Disassemble Vent Sections • Vertical runs originating off the top of the appliance, with no offsets, must be supported every 8 ft. (2.44 m) after the maximum allowed 25 ft. (7.62 m) of unsupported rise. • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown in Figure 10.11. • Vertical runs originating off the rear of the appliance, or after any elbow, must be supported every 8 ft. (2.44 m).
F. Install Decorative Ceiling Components (SLP only) LEVEL A decorative ceiling thimble can be installed on a flat ceiling through which the vent passes. The decorative ceiling thimble is used to cover the firestop. CATHEDRAL CEILING SUPPORT BOX • Seal the gap between the vent pipe and firestop using high temperature silicone (300ºF minimum continuous exposure rating) to prevent cold air infiltration.
G. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. CAULK • Slide the roof flashing over the pipe sections extending through the roof as shown in Figure 10.15. HORIZONTAL OVERHANG 2 FT. MIN. 20 INCHES MIN. VERTICAL WALL LOWEST DISCHARGE OPENING Figure 10.15 GAS DIRECT VENT TERMINATION CAP X 12 ROOF PITCH IS X/ 12 H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING H.
I. Install Vertical Termination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner flue of the pipe section while placing the outer collar of the cap over the outer flue of the pipe section. • Secure the cap by driving three self-tapping screws (supplied) through the pilot holes in the outer collar of the cap into the outer flue of the pipe. See Figure 10.17. K.
L. Install Horizontal Termination Cap (DVP and SLP Pipe) WARNING! Risk of Fire! The telescoping flue section of the termination cap MUST be used when connecting vent. • 1-1/2 (38 mm) minimum overlap of flue telescoping section is required. Failure to maintain overlap may cause overheating and fire. Note: When using termination caps with factory-supplied heat shield attached, no additional wall shield firestop is required on the exterior side of a combustible wall.
11 Gas Information A. Fuel Conversion C. Gas Connection • Make sure the appliance is compatible with available gas types. • Refer to Reference Section 16 for location of gas line access in appliance. • Conversions must be made by a qualified service technician using Hearth & Home Technologies specified and approved parts. • Gas line may be run through knockout(s) provided. B. Gas Pressure • Optimum appliance performance requires proper input pressures.
12 Electrical Information A. Wiring Requirements B. Intellifire Ignition System Wiring NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA C22.1. • Wire the appliance junction box to 110-120 VAC. This is required for use of optional accessories (standing pilot ignition) or proper operation of the appliance (Intellifire ignition).
IGNITION MODULE 3 VAC INTERMITTENT PILOT IGNITOR I S NOTE: 1. Ignition module, valve, pilot, and wall switch operate on 3 volts. 110-120 VAC is required at junction box unless equipped with battery back-up. TRANSFORMER 3 VAC WHITE NEUTRAL HOT PLUG IN ORANGE GROUND TO FIREPLACE CHASSIS K AC BL D RE WIRES (TO BROWN) GREEN ORANGE BATTERY PACK WIRE ASSEMBLY VALVE Figure 12.2 Intellifire Ignition Wiring Diagram with Wall Switch or Thermostat IGNITION MODULE 3 VAC NOTE: 1.
PILOT THERMOPILE THERMOCOUPLE PIEZO RED THERMOSTAT WIRE ASSEMBLY WHITE VALVE Figure 12.4 Standing Pilot Ignition Wiring Diagram E. Electrical Service and Repair WARNING! Risk of Shock! Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Romex Connector WARNING! Risk of Shock! Replace damaged wire with type 105° C rated wire. Wire must have high temperature insulation.
13 Finishing A. Splatter Guard The splatter guard is a piece of corrugated material used to protect the appliance during the installation process before finishing work on the whole hearth is complete. Splatter guards may be factory installed or accompany the decorative front of the unit, depending on the fireplace model. Splatter guards must be removed before appliance is fired. WARNING! Risk of Fire! Close the ball valve before installing the splatter guard to prevent accidental lighting.
Step 5. Fold bottom flap along score line as indicated in Figure 13.6 and tuck into valve access area of appliance. Splatter guard should fit securely on front of unit. Figure 13.9 Once plumbing and wiring are complete on the fireplace, the lower access panel may be closed until the time that the splatter guard must be removed for firing the appliance. Figure 13.6 Figure 13.10 To Close the Lower Access Panel: Figure 13.7 Step 6.
B. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clearances as specified. Framing closer than the minimums listed must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.) Failure to comply could cause fire. CEILING All measurements are in inches. 12 10 9 5 3 6 7 8 32 5 6 7 8 2-7/8 IN. MINIMUM 3 FT. MAXIMUM Note: Clearance from opening to perpendicular wall. 11 4 4 1/2 IN. MINIMUM 9 10 11 12 Figure 13.
C. Facing Material • Metal front faces may be covered with non-combustible materials only. • Facing and/or finishing materials must not interfere with air flow through louvers, operation of louvers or decorative fronts, or access for service. • Facing and/or finishing materials must never overhang into the glass opening. TOP SEAL JOINT SIDE SEAL JOINT 3 IN. (76 mm) • Observe all clearances when applying combustible materials.
D. Decorative Fronts Only decorative fronts certified for use with this appliance model may be used. Contact your dealer for a list of decorative fronts that may be used. Once you have determined what kind of decorative front and finishing material is going to be used on the fireplace, use the information below which shows the decorative front models and the non-combustible finishing material thickness allowed. FRONT FACE OF FIREPLACE 1 in.
E. Elevated Hearth Systems Use the table below to identify the hearth system that will be used. The table will also help identify effects on the various dimensions. Some hearth systems will elevate the appliance off the floor at a given dimension. For example, if appliance will be used with a Kenwood Cabinet with Base, the appliance will be elevated 9-1/4 in. The 9-1/4 in. elevation will also have to be added to the following: Wall penetration referenced in Figure 8.
14 Appliance Setup A. Remove Fixed Glass Assembly Placing the Lava Rock See Section 14.G. See Section 14F for Lava Rock placement instructions. B. Remove the Shipping Materials • Place lava rock on base pan. Do NOT place on burner top. Remove shipping materials from inside or underneath the firebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the firebox or underneath in the control cavity. D.
F. Install the Log Assembly If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately, refer to the following instructions. Log Set Assembly: LOGS-550-E, 750-E, 950-E Model: SL-550TR-E, 750TR-E, 950TR-E, SL-550TV-E, SL-750TV-E, SL-950TV-E Note: Figure 1 illustrates the recommended gap between the burner and the lava rock retainer. 3/8 in. Burner Carefully remove the logs from the packaging. CAUTION: LOGS ARE FRAGILE! Handle with care.
Log should touch lava rock retainer 3 3 Pin hole Figure 6 Figure 7 Mate shoulder screw with pin hole Log #3: Locate the pin hole on the underside of log #3. Mate the pin hole with the shoulder screw located on the burner top. Push the left end of log # 3 toward the back of the firebox until it touches the lava rock retainer. Bump Bump Swing knot towards log #3 5 4 Figure 8 Mate notch with grate tine Log #4: Locate the notch at the end of log # 4. Mate the notch with the tine as shown above.
G. Fixed Glass Assembly I. Air Shutter Setting WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches. This appliance has an adjustable air shutter (which controls the primary air) factory set for the minimum vertical vent run (see Figure 14.4).
15 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service technician in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician. Contact your dealer to arrange a service call by a qualified service technician. A.
Troubleshooting (continued) Symptom 3. (Continued) Possible Cause Corrective Action C. Valve. Turn the valve knob to the ON position. Place the ON/ OFF switch in the ON position. Take a reading with a millivolt meter at the thermopile terminals. The millivolt meter should read greater than 125mV. If the reading is acceptable, and if the burner does not come on, replace the gas valve. D. Plugged burner orifice. Check the burner orifice for stoppage. Remove stoppage. E. Wall switch or wires.
B. Intellifire Ignition System Symptom Possible Cause 1. Pilot won’t light. A. Incorrect wiring. The ignitor/module makes noise, but no B. Loose connections or electrical spark. shorts in the wiring. 2. Pilot won’t light, there is no noise or spark. 3. Pilot sparks, but Pilot will not light. 66 Corrective Action Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are connected to correct terminals on module and pilot assembly.
Intellifire Ignition System - (continued) Symptom 4. Pilot lights but continues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot flame has been lit, flame rectification has not occurred.) Possible Cause A. A shorted or loose connection in flame sensing rod. Corrective Action Verify all connections to wiring diagram in manual. Verify connections underneath pilot assembly are tight.
16 Reference Materials A. Appliance/Decorative Front Dimension Diagrams Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5.
O N P Q M L ØR GAS LINE ACCESS ØK C D V I E J H F S B T U A G ELECTRICAL ACCESS SL-950TR-E Location Inches Millimeters A 48 1218 B 43 1092 C 39-1/16 993 D 23-9/16 599 E 41-9/16 1056 F 3-9/16 90 G 6-7/8 174 H 30-7/8 785 I 41-7/8 1063 J 43-15/16 1117 K 8 203 L 8-13/16 223 M 16-5/16 415 N 1/2 13 O 37-3/4 959 P 18-7/8 478 Q 15-11/16 406 R 6-5/8 168 S 2-3/16 55 T 6 152 U 1 25 V 37-9/16 955 Figure 16.
FOLIO DECORATIVE FRONT C D B E F A G 550 750 950 A B C D E F G in. 30-15/16 28-9/16 27-1/2 19-15/16 30-1/16 6-1/2 1-5/16 mm 785 728 699 505 763 164 34 in. 35-13/16 32-1/16 32-7/16 23-1/8 33-9/16 6-3/4 1-5/16 mm 909 814 823 587 852 172 34 in. 42-13/16 36-1/8 39-1/16 23-1/2 37-9/16 7-7/8 1-1/8 mm 1087 918 992 596 953 199 31 CHATEAU/HALSTON DECORATIVE FRONTS C D Y B E A F X 550 750 A B C D E F X Y in.
CLEAN FACE DECORATIVE FRONTS C B D E G F A 550 750 in. A B C D E F G 30-13/16 23-5/16 26-9/16 18-11/16 25-7/16 3-1/2 4-9/16 mm 782 592 674 474 645 88 116 in. 35-13/16 26-13/16 31-1/2 22-3/16 28-15/16 3-1/2 4-9/16 mm 909 681 800 563 734 88 116 Figure 16.5 Appliance Dimensions - Clean Face Decorative Front Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev.
B. Vent Components Diagrams Pipe Effective Height/Length DVP Pipe (see chart) Effective Length Inches Millimeters DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 10-1/2 in. (267 mm) 45 ° 4-7/8 in. (124 mm) DVP48 48 1219 DVP6A 3 to 6 76 to 152 10-7/8 in. (276 mm) DVP12A 3 to 12 76 to 305 DVP45 (45º Elbow) 11-3/8 in. (289 mm) 10 in. (254 mm) 1 in. (25 mm) 20-3/4 in. (527 mm) 7-3/8 in. (187 mm) 10 in. (254 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) Tab=1 in.
B. Vent Components Diagrams (continued) Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B will be required. 8 in. (203 mm) Heat Shield 15-1/8 in. (384 mm) Term Cap Minimum Effective Length Maximum Effective Length 3-1/8 in. 4-5/8 in.
B. Vent Components Diagrams (continued) 31 in. (787 mm) 13-1/4 in. (337 mm) 24-5/8 in. (625 mm) 27-1/2 in. (699 mm) 24-5/8 in. (625 mm) 13-1/4 in. (337 mm) RF6M Roof Flashing Multi-pak RF12M Roof Flashing Multi-pak 5 in. (127 mm) 13-3/4 in. (349 mm) 11-7/8 in. (302 mm) 13-7/8 in. (352 mm) 13-3/4 in. (349 mm) DVP-BEK2 DVP-HPC Cap Brick Extension BEK Trap Cap Brick Extension 11-5/8 in. (295 mm) 12-1/8 in. (308 mm) 7-1/8 in. (181 mm) 5-3/4 in.
B. Vent Components Diagrams (continued) 7-3/8 in. (187 mm) 1-1/2 in. (38 mm) 9 in. (229 mm) 2-3/4 in. (70 mm) 14 in. (356 mm) 12-1/2 in. (318 mm) 11-1/2 in. (292 mm) 17-3/4 in. (451 mm) 12-1/4 in. (311 mm) 6 in. 152 mm 16 in. (406 mm) PVK-80 12 in. (305 mm) (For use with IPI and DSI appliances only.) DVP-TB1 Basement Vent Cap 12 in. 305 mm 14 in. (356 mm) 16-7/8 in. (429 mm) 7-1/4 in. (184 mm) 12-1/2 in. (318 mm) 5-1/4 in. (133 mm) 12 in.
B. Vent Components Diagrams (continued) 8-1/8 in. (206 mm) 13 in. (330 mm) Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm 8-3/8 in. 213 mm 5-1/2 in. 140 mm 87° 3° 15 in. (381 mm) 10-1/2 in. 267 mm 10-7/8 in. 276 mm DVP-HRC-SS HORIZONTAL TERMINATION CAP Figure 16.6 DVP vent components WARNING Fire Risk. • When using SLP-HRC-SS termination cap on top vented fireplaces, a one foot minimum vertical vent section is required before installing first elbow.
B. Vent Components Diagrams (continued) 6-1/2 in. 165 mm 6-1/2 in. 165 mm 8-3/4 in. 222 mm 6-1/2 in. 165 mm 9-1/4 in. 235 mm 6 in. 152 mm 6-5/8 in. 168 mm SLP45 45° Elbow 6-5/8 in. 168 mm 9-7/8 in. 251 mm SLP90 90° Elbow Effective Height/ Length Effective Height/Length SLP PIPE 10-7/8 in.
B. Vent Components Diagrams (continued) Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B will be required. 8 in. (203 mm) Heat Shield 15-1/8 in. (384 mm) Term Cap Max Effective Length 12 in.
B. Vent Components Diagrams (continued) 13 in. 330 mm 14 in. 356 mm 1-5/16 in. 34 mm 13 in. 330 mm 10-9/16 in. 269 mm SLP-DCF-BK Ceiling Firestop Black SLP-CCS-BK Cathedral Ceiling Support Box-Black 12 in. 305 mm 14-1/16 in. 357 mm 12-1/2 in. 318 mm 14 in. 356 mm 7-1/2 in. 192 mm 10-3/4 in. 273 mm SLP-FLEX-TRAP Horizontal Termination Kit 10-11/16 in. 271mm 28-1/2 in. 724 mm SLP-TVHW Vertical Termination Cap 1 in. (25 mm) 7-1/4 in. (184 mm) 14 in. (356 mm) 3/8 in. (10 mm) 1 in.
B. Vent Components Diagrams (continued) Optional Wire Harness 13-5/8 IN. 346 mm DESCRIPTION 12-1/2 IN. 318 mm PART NUMBER 10 ft. PV Wire Harness PVI-WH10 20 ft. PV Wire Harness PVI-WH20 40 ft. PV Wire Harness PVI-WH40 60 ft. PV Wire Harness PVI-WH60 80 ft. PV Wire Harness PVI-WH80 100 ft. PV Wire Harness PVI-WH100 Note: Wire harnesses required to power the PVI-SLP connect to the appliance and are ordered separately from PVI-SLP. Contact your dealer to order. 20-3/4 IN.
SL-550TR-E C. Service Parts Service Parts Beginning Manufacturing Date: June 2007 Ending Manufacturing Date: Active 32” Gas Fireplace - DV Log Set Assembly 2 3 4 1 5 6 7 8 10 9 IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
SL-750TR-E Service Parts Beginning Manufacturing Date: June 2007 Ending Manufacturing Date: Active 36” Gas Fireplace - DV Log Set Assembly 2 4 1 3 5 6 7 8 10 9 IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
SL-550TR-E, SL-750TR-E Beginning Manufacturing Date: June 2007 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
SL-550TR-E, SL-750TR-E Service Parts Beginning Manufacturing Date: June 2007 Ending Manufacturing Date: Active #7 Valve Assembly 7.1 7.2 7.3 7.10 7.9 7.4 7.8 7.5 7.7 7.6 IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor. ITEM 7.
SL-550TR-E Service Parts Beginning Manufacturing Date: June 2007 Ending Manufacturing Date: Active 32” Gas Fireplace - DV Log Set Assembly 2 3 4 1 5 6 7 8 10 9 IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
SL-550TR-IPI-E Service Parts Beginning Manufacturing Date: June 2007 Ending Manufacturing Date: Active 32” Gas Fireplace - DV 6 Log Set Assembly 2 3 4 1 5 7 8 9 11 10 IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
SL-750TR-IPI-E Service Parts Beginning Manufacturing Date: June 2007 Ending Manufacturing Date: Active 36” Gas Fireplace - DV 6 Log Set Assembly 2 3 4 1 5 7 8 9 11 10 IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide Stocked at Depot model number and serial number when requesting service parts from your dealer or distributor.
SL-950TR-IPI-E Service Parts Beginning Manufacturing Date: June 2007 Ending Manufacturing Date: Active 42” Gas Fireplace - DV 6 Log Set Assembly 2 3 4 1 5 7 11 10 9 8 12 IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide Stocked at Depot model number and serial number when requesting service parts from your dealer or distributor.
Service Parts SL-550-IPI-E, SL-750-IPI-E, SL-950-IPI-E Beginning Manufacturing Date: June 2007 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
Service Parts SL-550-IPI-E, SL-750-IPI-E, SL-950-IPI-E Beginning Manufacturing Date: June 2007 Ending Manufacturing Date: Active #8 Valve Assembly 8.1 8.12 8.2 8.10 8.11 8.3 8.9 8.8 8.13 8.4 8.6 8.5 8.7 IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor. ITEM 8.
D. Contact Information Heat & Glo, a brand of Hearth & Home Technologies 7571 215th St, Lakeville, MN 55044 www.heatnglo.com Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com.