SPECIFICATIONS
*1 • The amount of humidifi cation changes in accordance with indoor and outdoor temperature and humidity.
The amount of humidifi cation increases as temperatures rises or humidity decreases.
The amount of humidifi cation decreases as temperatures decrease or humidity rises.
Measurement Conditions: 20 ºC, 30 % humidity (JEM1426)
*2 • The recommended room size is appropriate for operating the unit of maximum fan speed.
• The recommended room size is an area in which a given amount of dust particles can be removed in 30 minutes.
*3 Room size in which approximately 7000 ions per cubic centimeter can be measured in the centre of the room when the unit is placed next
to a wall, is running at MED mode settings, and is at a height of approximately 1.2 meters from the fl oor.
Standby Power
When the unit’s power plug is inserted in a wall outlet it consumes about 1.2 watts of standby power in order to
operate electrical circuits.
To conserve energy, unplug the power cord when the unit is not in use.
Model UA-HG60E UA-HG50E UA-HG40E
Power supply 220-240 V 50-60 Hz
Fan Speed Adjustment
MAX MED LOW MAX MED LOW MAX MED LOW
CLEAN
AIR
Fan Speed (m
3
/hour)
408 240 72 306 180 60 240 120 60
Rated Power (W)
72 38 5.0 53 26 5.0 31 12 5.0
Noise Level (dBA)
53 48 24 52 47 19 46 40 19
CLEAN AIR
&
HUMIDIFY
Fan Speed (m
3
/hour)
342 240 72 240 120 60 210 120 60
Rated Power (W)
55 40 6.5 33 14 6.5 24 14 6.5
Noise Level (dBA)
49 48 24 46 40 20 43 40 20
Humidifi cation
(mL/hour) *
1
630 470 200 450 300 150 400 300 150
Recommended Room Size (m
2
) *
2
~50 ~38 ~28
High density Plasmacluster ion
recommended room size (m
2
)
*
3
~35 ~28 ~21
Water Tank Capacity (L) 3.0 2.5 2.5
Sensors
Dust(sensitive) / Odour / Light /
Temperature & Humidity / Motion
Dust(sensitive) / Light /
Temperature & Humidity
Cord Length (m) 2.0
Dimensions (mm) 370 (W) × 293 (D) × 660 (H) 345 (W) × 262 (D) × 631 (H) 345 (W) × 262 (D) × 631 (H)
Weight (kg) 10.5 9.2 9.2