Service manual

UX-310DE
FO-730DE/NX-530DE
2 – 7
1 DTMF signal transmission level Binary input 1
2 (Low) No. = 16 8 4 2 1 1
3 12345 0
4 11010 1
5 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
1 DTMF signal transmission level Binary input 1
2 (High) No. = 16 8 4 2 1 1
3 12345 0
4 11000 0
5 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
Reading slice (Binary) Factory Light Dark
Darker in
setting
dark mode
1 No. 1 0 1 0 1 0
2 No. 2 0 0 1 1 0
Reading slice (Half tone) Factory Light Dark
Darker in
setting
dark mode
3 No. 3 0 1 0 1 0
4 No. 4 0 0 1 1 0
5 Line density selection Fine Standard 0 OPTION
6 Halftone gray scale selection 16 level 64 level 0 OPTION
7 MTF correction in half tone mode No Yes 0
8 Reserved 0
1 Number of rings for auto receive Binary input 0 OPTION
2 No. = 8 4 2 1 0
3 1234 0
4 0001 1
5 Automatic switching manual to auto Reception after 5 No reception 0
receive mode rings
6 Reserved 0
7 CI detection 13 Hz or more As is PTT 0
8 Reserved 0
1 Reserved 0
2 Reserved 0
3 Reserved 0
4 Reserved 0
5 Caller ID function Yes No 0 OPTION
6 Reserved 0
7 Reserved 0
8 Caller ID detect during CI off All times Only first 1
1 Tel/Fax Automatic switching mode Tel/Fax auto switch Switch to Fax 1
Pseudo ringing time at phone/fax 15sec 60sec 30sec 120sec OPTION
2 automatic switching mode No. 2 0 0 1 1 0
3 No. 3 0 1 0 1 0
4
Number of CNG signal detection at the
Twice Once 1
tel/fax automatic switching mode
5 Reserved 0
6 Reserved 0
7 Post answer tone (transmit in No Yes 0
Tel/Fax mode)
8 Reserved 0
SW
NO.
DATA
NO.
ITEM
Switch setting and function
1
0
Remarks
Initial setting
SW
l
B5
SW
l
B6
SW
l
C1
SW
l
D2
SW
l
D1
DE
SW
l
E1