Specifications

9. COPY QUALITY ADJUSTMENT
- General Information -
Image density is affected by the following factors:
(1) Light Intensity
(2) Bias Voltage
(3) Toner Density
(4) Grid Voltage
(5) Charge Corona Current
The items listed above must be kept in balance to maintain correct image
density.
In the field, image density should be adjusted first by changing the
exposure lamp voltage. If results are unsatisfactory, the bias voltage
can be changed. Also, if requested from the customer, the overall image
density can be changed by changing the toner density. Normally, this
should be kept at the normal position (factory setting).
The grid voltage and charge corona current are carefully adjusted at the
factory. Any adjustment out of the adjustment standard will result in
overtoning, toner scattering, dirty background, or light image density problem.
The grid voltage and charge corona current adjustment should be done only
when replacing the CC/G/B power pack or correct certain problems with
image density after checking the other possible causes.
1 December 1990
5-90