Specifications

SP MODE OVERVIEW
SP Mode Data When
Performed
Movement Check
5 Exposure Lamp OFF - EM
6 Jam Detection OFF - EM
8 Input Check (Refer to Sensor/Switch Data Check Table) EM
9 Output Check (Refer to Electrical Component Check Table) EM
Installation and/or Sales Demonstration
10 Color Developer Initial Setting - Replace-
ment
11 All Indicators ON - -
12 220V/240V Conversion 0: 220V
1: 240V
Installation
User Requests
15 Auto Reset Time 0: 1 min.
1: 3 min.
2: None
-
16 Count Up/Down 0: Up
1: Down
-
17 Auto Feed Station Shift 0: Auto Shift
1: Manual
-
19 ADS Priority 0: ADS
1: Manual
-
20 APS Priority (When turning on the main
switch) (A054 copier only)
0: APS
1: Manual
21 APS Priority (When the original is set on the
DF)
0: APS
1: Manual
-
22 SADF Shut-off Time 0: 5 sec.
1: 60 sec.
-
23 ADF Free Size 0: No 1: Yes -
24 Factory Used
25 Margin Adjustment in Duplex Mode 0: Yes 1: No -
27 A3 (DLT) Double Counter 0: Normal
1: Double
-
28 Sort Priority 0: Manual
1: Auto Sort
-
29 Fusing Temperature Control 0: ON/OFF
1: Phase
-
Copy Quality Check and/or Adjustment
30 Black Toner Supply Mode 0: Detect Mode
1: Fixed Mode
EM or PM
31 Black Toner Supply Ratio (Detect Mode) 0: 15% 1: 7%
2: 30% 3: 60%
EM or PM
32 Black Toner Supply Ratio (Fixed Mode) 0: 7.0% 1 3.5%
2:10.5% 3: 14.0%
EM or PM