Service manual

14
VC-A565U/H965U
Figure 4-1.
• Reassembly
1. Before installing the cassette housing control, short-
circuit between TP803 and TP802 provided at main
PWB, press the eject button. The master cam turns and
stops when the positioning mark appears. Fit the drive
lever to master cam through main chassis, and push up
the drive lever.
Figure 4-2.
2. Install in the reverse order of removal.
Notes:
1. In the case when you use the magnet screw driver, never
approach the magnet driver to the A/C head, FE head,
and drum.
2. When installing or removing, take care so that the
cassette housing control and tool do not contact the
guide pin or drum.
3. After installing the cassette housing control once per-
form cassette loading operation.
4-4 TO RUN A TAPE WITHOUT THE CASSETTE
HOUSING CONTROL ASSEMBLY
1. Remove the full-surface panel.
2. Short-circuit between TP803 and TP802.
3. Plug in the power cord.
4. Turn off the power switch.
(The pole bases move into U.L.position.)
5. Open the lid of a cassette tape by hand.
6. Hold the lid with two pieces of vinyl tape.
7. Set the cassette tape in the mechanism chassis.
8. Stabilize the cassette tape with a weight (500g) to
prevent floating.
9. Turn on the power switch.
10. Perform running test.
4-3 REMOVING AND INSTALLING THE CAS-
SETTE HOUSING
• Removal
1. In the cassette removing mode, remove the cassette.
2. Unplug the power cord.
3. Remove in the following numerical order.
a) Remove two screws 1.
b) Pull the drive lever slide and pull up the cassette
housing control.
Figure 4-3.
Note:
The weight should not be more than 500g.
To take out the cassette tape.
1. Turn off the power switch.
2. Take out the cassette tape.
1
Master cam
Push up
Drive lever
500g
Weight to prevent
float (500g)
Mechanism chassis