Service manual

VL-A111U/AH131U
VL-AH151U/AH161U
8
4-2. DISASSEMBLY OF THE VCR MAIN BODY
(1) Slide the “VCR lid knob” in the arrow direction, and slide the
VCR lid in the arrow direction as far as the cabinet L fastening
screw is visible. (Left figure) Since the connector of the
microphone is still connected, take care to prevent exces-
sively sliding the VCR lid.
<2. Disassembly of the cabinet L>
(3) Pull out the VCR lid shaft head which projects beyond the
surface of the VCR lid.
VCR lid shaft
VCR lid
Frame V
VCR lid shaft
<Detail of area A>
(2) The jig (example: slotted precision screwdriver) into contact
with the removal groove of the VCR lid shaft, and slide the
screwdriver with care to prevent damaging the VCR lid and
frame V.
(1) Remove one screw ((k)LX-HZ0063TAFN).
(2) Remove five screws ((b)LX-HZ0018TAFF).
(3) Turn the tilt frame C so that the screwdriver can be easily
inserted, and remove two screws ((i)XiPSN20P04000).
(4) Remove one screw ((i)XiPSN20P04000).
Cabinet L
FPC connector
(b)
(i)
(i)
Area A
(k)
VCR lid knob
VCR lid
Tilt frame C
(5) Remove the cabinet L partway, and disconnect the FPC
connector.
<1. Removal of the VCR lid shaft>