11 - 14
11
[4] Timing chart
The following shows the timing chart when the currently started up X-axis is decelerated and stopped
by direct operation.
Time
Speed
Pulse output
Direct operation startup
(n+02004)
Deceleration stop
(n+02013)
Positioning completed
(n+00027)
Busy flag
(n+00002)