User`s manual

13 - 9
13
2
**
At data
transfer
The value of
parameter 1 has
exceeded the setting
range.
The problem location
(address) in the
parameter is the
location marked "**".
Before startup, an
error is detected
and operation is not
started up.. During
operation, an error
is detected and
operation is
stopped.
Correct the
problem location
in the parameter,
and transfer the
block data to clear
the error.
3
**
At data
transfer
The value of
parameter 2 has
exceeded the setting
range.
The problem location
(address) in the
parameter is the
location marked "**".
Before startup, an
error is detected
and operation is not
started up.. During
operation, an error
is detected and
operation is
stopped.
Correct the
problem location
in the parameter,
and transfer the
block data to clear
the error.
Parameter 2 error
4
**
At data
transfer
The value of the speed
data has exceeded the
setting range.
An additional error is
displayed when the
value of the speed
data exceeds the
maximum speed at
interpolation in direct
operation.
The problem location
(speed No.) in the
speed data is the
location marked "**".
Before startup, an
error is detected
and operation is not
started up.. During
operation, an error
is detected and
operation is
stopped.
Correct the
problem location
in the speed data,
and transfer the
block data to clear
the error.
Speed data error
5
**
At data
transfer
The value of the
coordinate data has
exceeded the setting
range.
The problem location
(coordinate No.) in the
coordinate data is the
location marked "**".
Before startup, an
error is detected
and operation is not
started up.. During
operation, an error
is detected and
operation is
stopped.
Correct the
problem location
in the coordinate
data, and transfer
the block data to
clear the error.
Coordinate data
error
6
**
At data
transfer
The value of the step
data has exceeded
the setting range.
The problem location
(step No.) in the step
data is the location
marked "*".
Before startup, an
error is detected
and operation is not
started up.. During
operation, an error
is detected and
operation is
stopped.
Correct the
problem location
in the step data,
and transfer the
block data to clear
the error.
Step data error
70
*
71
*
At data
transfer
The value of the
dwell timer data
has exceeded the
setting range.
The problem
location in the
dwell timer data is
as follows.
Errors for dwell
timer data No.0 to
15 become 600 to
615.
Before startup, an
error is detected
and operation is not
started up.. During
operation, an error
is detected and
operation is
stopped.
Correct the
problem location
in the dwell timer
data, and transfer
the block data to
clear the error.
Dwell timer data
error
Parameter 1 error
Error code
Detection timing
Error item
Content/cause of error Operation state at error
Remedy