User`s manual

13 - 10
13
72
*
At data
transfer
The value of the M
output data has
exceeded the setting
range.
The problem location (M
output No.) in the
deceleration data is the
location marked "*".
Before startup, the
error is output and
operation is not
started up.. During
operation, the error
is output, and
operation is
stopped.
Correct the
problem location
in the M output
data, and transfer
the block data to
clear the error.
M output data error
73
*
At data
transfer
The value of the
acceleration time data
has exceeded the setting
range.
The problem location
(acceleration data No.) in
the acceleration data is
the location marked "*".
Before startup, the
error is output and
operation is not
started up.. During
operation, the error
is output, and
operation is
stopped.
Correct the
problem location
in the acceleration
data, and transfer
the block data to
clear the error.
Acceleration time
data error
74
*
At data
transfer
751 to 999
Reserved area
The value of the
deceleration time data
has exceeded the setting
range.
The problem location
(deceleration data No.) in
the deceleration data is
the location marked "*".
Before startup, the
error is output and
operation is not
started up.. During
operation, the error
is output, and
operation is
stopped.
Correct the
problem location
in the deceleration
data, and transfer
the block data to
clear the error.
Deceleration time
data error
Error code
Detection timing
Error item
Content/cause of error Operation state at error
Remedy