User`s manual

3 - 4
3
[2] Switches (MODE, INITIAL)
MODE
Rotary
switch
0 to 9
(4 bits)
INITIAL
Push
switch
Name Type Description of functions
Sets the operation mode:
0: Regular operation mode (startup axis enable display mode) *1
1: Regular operation mode (X-axis enable display mode)
2: Regular operation mode (Y-axis enable display mode)
3: Regular operation mode (Z-axis enable display mode)
4: Regular operation mode (A-axis enable display mode)
5: - (unused)
6: - (unused)
7: - (unused)
8: System maintenance mode (system version upgrade, etc.)
9: Setting prohibited
The INITIAL switch has the following two functions:
For initial start (same as restart by power ON
When the MODE switch is set to 0 to 4, and the INITIAL switch is
held down for at least 5 seconds, the data recorded to flash ROM
is read to RAM area (*2).
For initialization
When the MODE switch is set to 8, and the INITIAL switch is held
down for at least 5 seconds, RAM area is initialized (set to the
default or factory setting state).
*1 The latest startup data is indicated for the display when "10" is set.
[Example] When direct operation is applied on the Y-axis during program
operation on the X-axis, the information of the Y-axis is displayed.
Note, however, that the information of the first axis to be started up is not
indicated even during operation if the axis that started up later has stopped.
*2 Memory that is used during actual operation