User`s manual

4 - 2
4
4-2 Connecting connectors to this module
The following describes how to connect the CN1 connector for tool connection, CN2 connector for X-/
Y-axes and CN3 for Z-/A-axes (JW-14PS only).
[1] Connecting the CN1 connector for tool connection
Connect this connector to the third-party personal computer (Windows 95/98). Use the dedicated cable
and communications adapter (JW-100SA, sold separately) for connection.
JW-14PS
X
Y
Z
A
CW
CCW
READY
FAULT
9
8
7
6
5
4
3
2
1
0
MODE
INITIAL
CN1
CN2(X,Y)
CN3(Z,A)
S1.0
140 mm
80 mm
Personal computer
(DOS/V)
(9-pin connector)
*Exclusive cable (2 m or less)
Connector CN1 for tool
connection(CN1)
Connector
(D-Sub 25-pin)
JW-100SA
(Communications adapter)
Plug
(14-pin)
This module
(JW-12PS/14PS)
(Above figure is for JW-14PS.)
*The customer must prepare the exclusive cable. (See wiring diagram on following page.)