User`s manual
4 - 12
4
X (Z) axis pin 5
Y (A) axis pin 17
26,27
(common to
X, Y, Z, A axes)
CW open collector
pulse output
(
24V (-) input is common.
)
24 VDC (-) input
(COM for output)
X (Z) axis pin 30
Y (A) axis pin 42
FG
CCW open collector
pulse output
(24V (-) input is common.)
JW-12PS(JW-14PS)
24 VDC
power supply
-+
CW pulse input
Driver side
CCW pulse input
Suitable resistance
value is required.
Open collector of
pulse module can be
driven up to 30 mA.
Be sure to wire to FG using a shielded
pulse output signal line.
(Connected the shielded lead to the
shield of the connector.)
X (Z) axis pin 3
Y (A) axis pin 15
CW pulse differential output (+)
X (Z) axis pin 28
Y (A) axis pin 40
CW pulse differential output (-)
CW pulse differential input (+)
CW pulse differential input (-)
X (Z) axis pin 4
Y (A) axis pin 16
CCW pulse differential output (+)
X (Z) axis pin 29
Y (A) axis pin 41
CCW pulse differential output (-)
CCW pulse differential input (+)
CCW pulse differential input (-)
FG
Driver side
CCW pulse input
JW-12PS(JW-14PS)
AM26LS31 or equivalent product
AM26LS32 or
equivalent product
X (Z) axis pin 6
Y (A) axis pin 18
26,27
(common to
X, Y, Z, A axes)
Clear deviation output
(
24 V (-) input is common
.)
24 VDC (-) input
(COM for output)
X (Z) axis pin 31
Y (A) axis pin 43
FG
General-purpose output
(24 V (-) input is common.)
JW-12PS(JW-14PS)
Clear deviation input
Driver side
Servo ON input
General-purpose output can be
used as a servo ON contact as it
its application is not determined.
Suitable resistance
value is required.
Open collector of
pulse module can be
driven up to 30 mA.
24 VDC power
supply
-+
[6] Wiring of CW/CCW pulse output signals
(1) Wiring in an open collector connection with a general pulse driver
(2) Wiring in connection with general differential reception-type driver
[7] Wiring of clear deviation output/general-purpose output signals