User`s manual
5 - 5
5
The following shows the formats for each of the data items. (Setting data is annotated entirely in BCD.)
(1) M output range data (0 to 7)
Setting range of upper limit value/lower limit value: -9999999 to +9999999 (-9999999 to +9999999
pulses) in 1-pulse increments
Address
7
10
1
10
3
10
5
10
0
10
2
10
4
10
6
654
A/I Sign
3210
Bit
C+0000
C+0001
C+0002
C+0003
C+0004
C+0005
C+0006
C+0007
10
1
10
3
10
5
10
0
10
2
10
4
10
6
A/I Sign
Lower limit valueUpper limit value
(2) Acceleration time/deceleration time data
Setting range: 0 to 250000 (0 to 250000 ms) in 1-ms increments
Acceleration time data (1 to 8)
Address
7
10
1
10
3
10
5
10
0
10
2
10
4
6543210
Bit
D+0000
D+0001
D+0002
D+0003
• "Sign": plus=0, minus=1, absolute values independent of the "A/I" bit setting
• C is the leading address of each M output 0 to 7.
(3) Dwell timer data (01 to 16)
Setting range: 0 to 9999 (0 to 99990 ms) in 10-ms increments
Address
7
10
1
10
3
10
0
10
2
6543210
Bit
F+0000
F+0001
• D is the leading address of each acceleration time data 1 to 8.
Deceleration time data (1 to 8)
Address
7
10
1
10
3
10
5
10
0
10
2
10
4
6543210
Bit
E+0000
E+0001
E+0002
E+0003
• E is the leading address of each deceleration time data 1 to 8.