Service manual

XE-A201US
– 5 –
CHAPTER 2. OPTIONS
1. OPTIONS (No)
2. SERVICE OPTIONS (No)
3. SUPPLIES
4. SPECIAL SERVICE TOOLS
CHAPTER 3. MASTER RESET AND PROGRAM RESET
1. MASTER RESETTING
Master resetting clears the entire memory and resumes initial values.
Master resetting can be accomplished by using the following proce-
dure:
Procedure A: 1) Plugin the AC cord to the wall outlet.
2) Set the mode switch to REG position.
3) Let the ECR be witout the memory backup battery.
4) Unplug the AC cord from the wall outlet.
5) Wait over 1 minute for discharging.
6) Plugin the AC cord to the wall outlet.
The master reset can also be accomplished in the following case.
In case power failure occurs when the machine has no battery
attached to it, the master reset operation is automatically per-
formed after the power has been restored.
(This is because if power failure occurs with no battery attached to
the machine, all the memories are lost and the machine does not
work properly after power recovery; this requires the master reset
operation.)
2. PROGRAM RESETTING
(INITIALIZATION)
This resetting resumes the initial program without clearing memory.
This resetting can be operated at below sequence in PGM mode.
Procedure: 1) Unplug the AC cord from the wall outlet.
2) Wait over 1 muinite for discharging.
3) Set the mode switch to the PGM position.
4) While holding down the FEED key, plugin the AC
cord to the wall outlet.
Note: In case power failure occurs when the machine has no battery
attached to it, the master reset operation is automatically per-
formed after the power has been restored.
NO NAME PARTS CODE
PRICE
RANK
DESCRIPTION
1 Thermal roll paper TPAPR6656RC05 BA 5 ROLLS/PACK 70 φ
NO NAME PARTS CODE
PRICE
RANK
DESCRIPTION
1 RS-232 Loop-back connector UKOK-6705RCZZ BU
2 POS tools (IPL Software) UKOG-2360BHZZ