Specifications

Quick Start Reference Sheet
Sharp XG-MB70X
Revision A
DR-SHP32 – 10/26/04
SP Controls reserves the right to modify specifications without notice at any time.
NOTE: This one-page document is intended only as a quick reference for installation – please read
the SP Controls Application Note for a complete description of this projector driver prior to installation.
I. Driver Features
1. Input Selection Mapping
Selection 1: IR VIDEO
Selection 2: IR S-VIDEO
Selection 3: IR RGB 1
Selection 4: IR RGB 2
2. Hidden Function Mapping (Default Configuration)
Using the ON button as a shift key, press the following buttons to access the specified projector features.
Selection 1: AV MUTE TOGGLE
Selection 2: ENTER
Selection 3: ADJUST LEFT
Selection 4: ADJUST RIGHT
Off: MENU
Volume Up: ADJUST UP
Volume Down: ADJUST DOWN
3. Other Driver Features
Power Status Feedback Method RS-232 Power Polling
Control Wiring: RS-232 and IR-Emitter required
II. Wiring Specifications
1. RS-232:
Wire the Panel RS-232 port to a female DB9 as follows:
TX to 2
RX to 3
GND to 5
Connect this female DB9 to the included Sharp intermediate cable (labeled RS-232C) and connect
the mini-DIN end of the adapter to the projector port labeled RS-232C IOIOI.
2. Infrared Emitter:
Wire the Panel IR/Serial port to a female 1/8" Mini as follows:
IR/SER to tip
GND to ring
Connect to the included IR Emitter and attach the emitter bud to any projector IR window.
III. Additional Projector Information
Note: SP Controls strongly recommends using IR to control projector input selection. See the Application
Note below for more information.
Note: The following projector menu settings must be correctly set:
ECONOMY MODE must be set to OFF in the projector menu OPTIONS 1. RS232C must be set to 9600
(default) in the projector menu OPTIONS 2. LAN/RS232C must be set to ENABLE (default) in the
projector menu OPTIONS 2.
See the Special Control Note in Section II. Control Wiring below for more information.