Service manual

XL-520W/CP-520
– 14 –
Test Mode operation specification
3. Preset frequencies for various destinations (random preset memory)
BAND (CH)
1 FM 87.5MHz
2 FM 108.0MHz
3 FM 98.0MHz
4 FM 90.0MHz
5 FM 106.0MHz
• The unit used in the table above is Hz. K represents 1,000 times, and M represents 1,000,000 times.
• The hatched data shown in the table are not stored in the memory.
• FM is stereo mode.
Note: Keys which are effective in Test Mode
• Main unit keys: VOLUME UP/DOWN, BAND, TUNING UP, POWER, MEMORY, CLEAR,
PRESET UP/DOWN
• Remote controller keys:
VOL UP/DOWN, BAND, TUNING UP/DOWN, POWER, MEMORY, CLEAR, PRESET UP/DOWN
4. Electronic volume Test Mode (TEST 4)
After the Test Mode is set, the following display lights for one second.
1 FM 87.5MHz
2 FM 108.0MHz
3 FM 98.0MHz
4 FM 90.0MHz
5 FM 106.0MHz
When this mode has been set, -14dB (STEP17) is set, the preset equalizer is set to FLAT (EQ-3), the SRS mode is set to OFF,
and the start-up function is set to Tape.
1. The display is the same as that indicated in case of regular operation excepting when Test Mode is set.
2. The volume control with the Volume UP/DOWN key is only the following 3 steps, differing from the volume control in the regular
operation mode.
Volume — (STEP 0) Volume — 14dB (STEP 17) Volume — 0 (STEP 24)
3. The preset equalizer and SRS are switched if key operation is performed.
5. Timer Test Mode (TEST 5)
When the Test Mode is set, the following display lights for one second.
The current time and timer time are set in the following procedure, and timer playback is performed.
1. The present time is set to 1:00, the timer is set to ON time 1:02, OFF time 1:12, Function is set to Tape, Volume is set to STEP8.
One minute is counted in increments of second, and timer playback is performed. One step of Fade-in/out in this mode is
performed for 0.5 sec.
The display is the same as that appears in the regular timer operation.
2. After completion of timer playback test "TEST-5" indication (which appears when the mode is set) appears again and Standby
state is set. PLAY key entry is waited. If an entry is detected, the SLEEP timer is set to 2 minutes, and Function is set to
Tape, so that playback is started at once. Volume is set to STEP8, and 10 seconds are counted down in decrements of
second. One step of Fade-out is 0.5 sec.
The display is the same as that appears in the regular sleep playback mode.
3. After completion of SLEEP test, the Test Mode is turned off, and regular standby mode is set, so that the Test Mode ends.
6. LCD Test Mode (TEST 6)
When the LCD Test Mode is set, all the LCD segments light.
BAND (CH)
10 kHz SPAN
100 kHz SPAN
BAND (CH)
6 AM 531 kHz
7 AM 1,602 kHz
8 AM 990 kHz
9 AM 603 kHz
10 AM 1,404 kHz
6 AM 530 kHz
7 AM 1,620 kHz
8 AM 990 kHz
9 AM 600 kHz
10 AM 1,400 kHz
BAND (CH)
9 kHz SPAN
10 kHz SPAN