Installation guide
KINO-6612 Mini-ITX Motherboard
Page 90
The RS-232 or RS-422/RS-485 Serial Port Select jumper sets the communication protocol
used by the second serial communications port (COM2) as RS-232 or RS-422/RS-485.
The RS-232 or RS-422/RS-485 Serial Port Select settings are shown in
848H850HTable 5-6.
RS-232/485 Select Description
Short 1-2 RS-232 Default
Short 2-3 RS-422/485
Table 5-6: RS-232/485 Serial Port Select Jumper Settings
The RS-232/485 Serial Port Select jumper location is shown in 849H851HFigure 5-12.
Figure 5-12: RS-232/485 Serial Port Select Jumper Location
5.6 Chassis Installation
5.6.1 Airflow
WARNING:
Airflow is critical to the cooling of the CPU and other onboard
components. The chassis in which the KINO-6612 must have air vents
to allow cool air to move into the system and hot air to move out.