Installation Guide

INSTALLATIONGUIDELINESFORVINYLPLANKANDTILE
TABLEOFCONTENTSSECTION:
1. TESTBEFORESTARTINGINSTALLATIONS
2. MATERIALSTORAGEANDHANDLING
3. SUBSTRATES
4. SHAWADHESIVES
5. INSTALLINGRESILIENTTILE&PLANKPRODUCTS
6. ARRAYGROUT
7. WARRANTY
1.TESTBEFORESTARTINGINSTALLATION
Note:Allsubstratestoreceivemoisturesensitivefloorcoveringmustbetestedformoisture.
CONCRETESUBSTRATES:
AllconcretesubstratesshouldbetestedforIRH(InternalRelativeHumidity)accordingtoASTMF2170.
CalciumChloridetestsmaybeconductedinadditiontoIRHandmustbeperformedperthelatesteditionofASTMF1869.
NEWANDEXISTINGCONCRETESUBFLOORSSHOULDMEETTHEGUIDELINESOFTHELATESTEDITIONOFACI302ANDASTMF710,“STANDARD
PRACTICEFORPREPARINGCONCRETEFLOORSTORECEIVERESILIENTFLOORING”AVAILABLEFROMTHEAMERICANSOCIETYFORTESTINGAND
MATERIALS,100BARRHARBORDRIVE,WESTCONSHOHOCKEN,PA19428;6108329585;HTTP://WWW.ASTM.ORG.
a. Substratesshallbesmooth,structurallysound,permanentlydry,cleanandfreeofallforeignmaterialsuchasdust,wax,solvents,paint,
grease,oils,oldadhesiveresidue,curingandhardening/curingcompounds,sealersandotherforeignmaterialthatmightprevent
adhesivebond.
b. Concretefloorsshallbeflatandsmoothwithin
1/8"in6feetor3/16”in10feet.
c. FNumberSystem:OverallvaluesofFF36/FL20maybeappropriateforresilientfloorcoverings.
d. ASTMF2170IRH(InternalRelativeHumidity)arerequiredfortheShawwarranty.Threetestsmustbeconductedforareasupto
1000SF,
andoneadditionaltest,foreachadditional1000SF.
e. MoistureVaporEmission Rate(MVER)
200&KwikflashAdhesive‐maynotexceed85%RH.
S150&4100Adhesive‐maynotexceed90%RH.
f. UseonlyPortlandbasedpatchingandlevelingcompounds.DonotinstallShawresilient
flooringovergypsumbasedpatchingand/or
levelingcompounds.
g. PerformBondtestingtodeterminecompatibilityofadhesivetothesubstrate.Shaw9050primercanbeutilizedtopromoteadhesion.
h. Workingandopentimesofadhesivesmayvarybasedonjobconditions,substrate,temperature,andhumidity.
i. Areastoreceive
flooringshouldbeadequatelylightedduringallphasesoftheinstallationprocess.
j. Itisrecommendedthatresilientfloorcoveringinstallationshallnotbeginuntilallothertradeshavecompleted.
TEMPERATURE‐AMBIENT:
a. Controlledenvironmentsarecritical.FullyfunctionalHVACsystemsarethebestwaytoensuretemperatureandhumidity
control.
DONOTinstallresilientflooringproductsuntiltheworkareacanbetemperaturecontrolled.
ThepermanentHVACsystemturnedonandsettoaminimumof65°F(20°C)oramaximumof85°F,foraminimumof7days
priorto,during,andafterinstallation.Oncetheinstallation
iscompletethe temperatureshouldnotexceed85°F.
PH:
a. ConcretefloorsmustbetestedperthelatesteditionofASTMF710.
PHreadingmustnotexceed9.0.
Readingsbelow5.0andinexcessof9.0affectresilientflooringandadhesivesnegatively.
Rinsingthesurfacewith
clearwatermayloweralkalinity.“DAMPMOP”
Shaw9050anacrylicsolutioncanbeutilizedtocorrecthighPHreadings.

Summary of content (7 pages)