INSTALLATION GUIDELINES FOR VERSA FIT™ VINYL PLANK
1.TESTBEFORESTARTINGINSTALLATIONS
Allsubstratestoreceivemoisturesensitivefloorcoveringmustbetestedfor
moisture.
CONCRETESUBSTRATES:
CalciumChlorideTestsmustbeperformedperthelatesteditionofASTM
F1869andshallnotexceed8lb.per1000sfin24hrs.
InternalRelative
HumidityRHTestmustbeperformedperthelatest
editionofASTMF2170andshallnotexceed85%.
Newandexistingconcretesubfloorsshouldmeettheguidelinesofthelatest
editionofACI302andASTMF710,"StandardPracticeforPreparingConcrete
FloorstoReceiveResilientFlooring"
availablefromtheAmericanSocietyfor
TestingandMaterials,100BarrHarborDrive,WestConshohocken,PA19428;
6108329585;http://www.astm.org.
a. Substratesshallbesmooth,structurallysound,permanentlydry,cleanand
freeofallforeignmaterialsuchasdust,solvents,grease,oils,oldadhesive
residue.
b. Concretefloorsshallbeflatandsmoothwithin1/8”in10feet.
c. FNumberSystem:OverallvaluesofFF36/FL20maybe
appropriatefor
resilientfloorcoverings.
d. ASTM1869‐Threecalciumchloridetestsshouldbeconductedforareas
upto1000ft
2
.Oneadditionaltestrequiredperadditional1000ft
2
.
e. ASTM2170‐IRH(InternalRelativeHumidityTest),threetestsshouldbe
conductedforareasupto1000ft
2
.Oneadditionaltest,foreachadditional
1000ft
2
.
f. Moisturevaporemissionratemaynotexceed8lb./1000ft2/24hoursor
85%usingarhtestforlooselayinstallation
g. Followadhesiveguidelinesformoisture limitswheninstallingusing the
gluedownmethod.
UseonlyPortlandbasedpatchingandlevelingcompounds.DonotinstallShaw
resilientflooringovergypsumbasedpatchingand/orlevelingcompounds.
LIGHTWEIGHTCONCRETE:
InternalRelativeHumidityTestsmustbeperformedperthelatesteditionof
ASTMF2170.
a. Threeinternalrelativehumiditytestsshouldbeconductedforareasupto
1000ft
2
.Oneadditionaltest,foreachadditional1000ft
2
.
b. Internalrelativehumidityratemaynotexceed85%.PerASTMF710.
c. Surfacemustbedry,clean,smooth,freeofalldust,andstructurallysound.
WOODSUBSTRATES:
Amoisturetestisrequiredusingapintypemoisturemeter.Themaximum
allowablemoisturecontentmustnotexceed15 %.
a. Woodsubfloorsmustbestructurallysoundandincompliancewithlocal
buildingcodes.
b. Woodsubfloorsshouldbesuspendedwithaminimumof18”ofwell
ventilatedairspacebelow.
c. Crawlspacesmusthaveavaporretardercoveringtheground.
d. Woodsubfloorsdirectlyfastenedtoconcrete,or
sleeperconstruction,are
notrecommended.
e. APAratedSturdiIFloorpanelsaredesignedascombination
subfloor/underlayment,butexposuretoconstructionconditionsincluding
weathermaynecessitateinstallationofa1/4”underlaymentpanelpriorto
resilientflooringinstallation.
f. SHAWresilientflooringisnotrecommendeddirectlyoverfireretardant
treatedplywoodor
preservativetreatedplywood.Thematerialsusedto
treattheplywoodmaycauseproblemswithadhesivebonding.An
additionallayerofAPArated1/4"thickunderlaymentshouldbeinstalled.
TEMPERATURE‐AMBIENT:
Controlledenvironmentsarecritical.FullyfunctionalHVACsystemsarethebest
waytoensuretemperatureandhumiditycontrol.
Do
notinstallresilientflooringproductsuntiltheworkareacanbe
temperaturecontrolled.
Minimuminstallationtemperatureis65°Fwithamaximuminstallation
temperatureof85°F.
TEMPERATURERADIANTHEAT:
Radiantheatedsubstratesmustnotexceed85°F(29°C)surfacetemperature.
Severaldayspriortoinstallingresilientproductsovernewly
constructed
radiantheatedsyst ems,makesuretheradiantsystemhasbeenonand
operatingatmaximumtemperaturetoreduceresidualmoisturewithinthe
concrete.
Threedayspriortoinstallationlowerthetemperatureto65degrees,24
hoursafterinstallationgraduallyincresethetemperatureinincrementsof
Ftoavoid
overheating.
Aftercontinuousoperationoftheradiantsystem,ensurethesurfaceof
thefloordoesnotexceed85
o
F.
Radiantheatcomponentsmustbeaminimumof½”separatedfromthe
VersaFitPlank.
Useofaninfloortemperaturesensorisrecommendedtoavoid
overheating.
PH:
ConcretefloorsmustbetestedperthelatesteditionofASTMF710.
PHreadingmustnotexceed
10.0.
Readingsbelow7.0andinexcessof10.0affectresilientflooringand
adhesives.
Rinsingthesurfacewithclearwateristhebestwaytoloweralkalinity.
“DAMPMOP”
Note:Itmaynotbethefloorcoveringinstaller’sresponsibilitytoconductthe
tests.Itis,however,thefloorcovering
installer’sresponsibilitytomakesure
thesetestshavebeenconductedandthattheresultsareacceptablepriorto
installingthefloorcovering.Whenmoisturetestsareconducted,itindicates
theconditionsonlyatthetimeofthetest.
2.JOBSITECONDITIONS
a. Itisrecommendedthatresilientfloorcovering
installationshallnotbegin
untilallothertradesarecompleted.
b. Areastoreceiveflooringshallbeclean,fullyenclosed,withthepermanent
HVACsetatauniformtemperaturerangeof65
o
Fto85
o
Fandmaintained
followingtheinstallation.
c. Areastoreceiveflooringshouldbeadequatelylightedduringall phasesof
theinstallationprocess.
d. Floorsshallbesmooth,permanentlydry,cleanandfreeofallforeign
materialsuchasdust,solvents,grease,oils,oldadhesiveresidue.