Instructions

EN
USER AND SAFETY GUIDE
2 CIRCUIT WI-FI RELAY SWITCH
SHELLY PRO 2
Read before use
This document contains important technical and safety infor-
mation about the device, its safety use and installation.
CAUTION! Before beginning the installation, please read this
guide and any other documents accompanying the device care-
fully and completely. Failure to follow the installation procedures
could lead to malfunction, danger to your health and life, violation
of the law or refusal of legal and/or commercial guarantee (if
any). Allterco Robotics EOOD is not responsible for any loss or
damage in case of incorrect installation or improper operation
of this device due to failure of following the user and safety in-
structions in this guide.
Product Introduction
Shelly® is a line of innovative microprocessor-managed devic-
es, which allow remote control of electric appliances through a
mobile phone, tablet, PC, or home automation system. Shelly®
devices can work standalone in a local Wi-Fi network or they
can also be operated through cloud home automation services.
Shelly® devices can be accessed, controlled and monitored
remotely from any place the User has Internet connectivity,
as long as the devices are connected to a Wi-Fi router and the
Internet. Shelly® devices have integrated web servers, through
which the user may adjust, control and monitor them. The cloud
function could be used, if it is activated through the web server
of the device or the settings in the Shelly Cloud mobile applica-
tion. The user can register and access Shelly Cloud using either
Android or iOS mobile application, or with any internet browser
at https://my.shelly.cloud/
Shelly® Devices have two Wi-Fi modes - Access Point (AP) and
Client mode (CM). To operate in Client Mode, a Wi-Fi router
must be located within the range of the device. Devices can
communicate directly with other Wi-Fi devices through HTTP
protocol. An API is provided by Allterco Robotics EOOD.
For more information, please visit:
https://shelly-api-docs.shelly.cloud/#shelly-family-overview
Control your home with your voice
Shelly® devices are compatible with Amazon Echo and Google
Home supported functionalities. Please see our step-by-step
guide on: https://shelly.cloud/support/compatibility/
Shelly® Pro Series
Shelly® Pro series is a line of Devices suitable for homes, oc-
es, retail stores, manufacturing facilities, and other buildings.
Shelly® Pro devices are DIN mountable inside the breaker box,
and highly suitable for new building construction. Connectivity
for all Shelly® Pro devices can be through Wi-Fi or LAN Internet
connection, and Bluetooth can be used for the inclusion pro-
cess.
Legend
Device terminals:
O1: Load circuit 1 output terminal
O2: Load circuit 2 output terminal
I1: Load circuit 1 input terminal
I2: Load circuit 2 input terminal
SW1: Switch (controlling O1*) input terminal
SW2: Switch (controlling O2*) input terminal
L: Live (110-240V) terminal
N: Neutral terminal
+12: 12V (10.5V to 13.5V) DC power supply terminal
LAN: Local Area Network RJ 45 connector
Wires:
N: Neutral wire
L: Live (110-240V) wire
L1(A): Load circuit 1 live (110-240V) wire
L2(B): Load circuit 2 live (110-240V) wire
L3(C): Device power supply live (110-240V) wire
+: 12 V DC power supply positive wire
-: 12 V DC power supply negative wire
* Can be recongured
Installation Instructions
The Shelly Pro 2 smart relay (the Device) by Allterco Robotics
EOOD is intended to be mounted into a standard switchboard
on DIN rail, next to the circuit breakers. Shelly can work as a
standalone device or as an accessory to a home automation
controller. Shelly Pro 2 is a two-channel relay with dry contacts
and two-phase support.
CAUTION! Do not install the device at a place that is possible
to get wet.
CAUTION! Danger of electrocution. Mounting/ Installation of
the Device to the power grid has to be performed with caution, by
a qualied electrician.
CAUTION! Danger of electrocution. Every change in the con-
nections has to be done after ensuring there is no voltage pres-
ent at the Device terminals.
CAUTION! Do not connect the Device to appliances exceed-
ing the given max load!
CAUTION! Use the Device only with a power grid and appli-
ances which comply with all applicable regulations. A short cir-
cuit in the power grid or any appliance connected to the Device
may damage the Device.
CAUTION! Connect the Device only in the way shown in these
instructions. Any other method could cause damage and/or in-
jury.
CAUTION! Тhe Device may be connected to and may control
electric circuits and appliances only if they comply with the re-
spective standards and safety norms.
RECOMMENDATION Connect the Device using solid sin-
gle-core cables with increased insulation heat resistance not
less than PVC T105°C.
Connect the Device to the power grid and install it in the switch-
board as shown in the schemes and following the Safety In-
structions.
Before starting installing/mounting the Device , wire check
that the breakers are turned off and there is no voltage on their
terminals. This can be done with a phase meter or multimeter.
When you are sure that there is no voltage, you can proceed to
wiring the cables.
If you are using AC for the Device and the load circuits (g.1),
connect the N terminal to the Neutral wire and the L terminal to
the Device power supply circuit breaker.
Connect the two switch circuits to the S1 and S2 input terminals
and the Device power supply circuit breaker.
Connect the rst load circuit to the O1 terminal and the Neutral
wire. Connect the I1 terminal to the rst load circuit breaker.
Connect the second load circuit to the O2 terminal and the
Neutral wire. Connect the I2 terminal to the second load circuit
breaker.
Two different phases can be used for the two load circuits and
a third one for the Device power supply circuit.
If you are using AC to power the Device and switch mixed DC
and AC load circuits (g.2), connect the N terminal to the Neu-
tral wire and the L terminal to the Device power supply circuit
breaker.
Connect the two switch circuits to the S1 and S2 input terminals
and the Device power supply circuit breaker.
Connect the DC load circuit to the O1 terminal and one of the DC
load circuit power supply wires. Connect the I1 terminal to the
other DCload circuit power supply wire.
CAUTION The DC load circuit voltage should not exceed 30 V
and the current should not exceed 12 A.
Connect the AC load circuit to the O2 terminal and the Neutral
wire. Connect the I2 terminal to the AC load circuit breaker.
Two different phases can be used for the AC load circuits and
for the Device power supply circuit.
If you are using AC to power the Device and switch two DC load
circuits (g.3), connect the N terminal to the Neutral wire and
the L terminal to the Device power supply circuit breaker.
Connect the two switch circuits to the S1 and S2 input terminals
and the Device power supply circuit breaker.
Connect the rst DC load circuit to the O1 terminal and one of
the rst DC load circuit power supply wires. Connect the I1 ter-
minal to the other rst DC load circuit power supply wire.
Connect the second DC load circuit to the O2 terminal and one
of the second DC load circuit power supply wires. Connect the
DE
BENUTZER- UND SICHERHEITSLEITFADEN
2-KREIS-WLAN-RELAISSCHALTER
SHELLY PRO 2
VOR BENUTZUNG LESEN
Dieses Dokument enthält wichtige technische und sicherheitsre-
levante Informationen über das Gerät, seine sichere Verwendung
und Installation.
ACHTUNG! Bevor Sie mit der Installation beginnen, lesen Sie
bitte diese Anleitung und alle weiteren dem Gerät beiliegenden
Unterlagen sorgfältig und vollständig durch. Die Nichtbeachtung
der Installationsanweisungen kann zu Fehlfunktionen, Gefahren für
Gesundheit und Leben, Gesetzesverstößen oder Verweigerung der
gesetzlichen und/oder kommerziellen Garantie (falls vorhanden)
führen. Allterco Robotics haftet nicht für Verluste oder Schäden im
Falle einer falschen Installation oder eines unsachgemäßen Betriebs
dieses Geräts aufgrund der Nichtbeachtung der Benutzer- und Si-
cherheitshinweise in dieser Anleitung.
PRODUKTEINFÜHRUNG
Shelly® ist eine Reihe innovativer Geräte, die die Fernsteuerung
von Elektrogeräten über ein Mobiltelefon, Tablet, PC oder Haus-
automationssystem ermöglichen. Shelly® kann eigenständig im
lokalen Wi-Fi-Netzwerk arbeiten, ohne von einem Heimautomati-
sierungscontroller verwaltet zu werden, oder es kann auch über
Cloud-Heimautomatisierungsdienste funktionieren. Auf Shelly®-
Geräte kann von jedem Ort, an dem der Benutzer über eine Inter-
netverbindung verfügt, aus der Ferne zugegriffen, sie gesteuert und
überwacht werden, solange die Geräte mit einem Wi-Fi-Router und
dem Internet verbunden sind.
Shelly® verfügt über einen integrierten Webserver, über den der Be-
nutzer das Gerät einstellen, steuern und überwachen kann. Shelly®
hat zwei Wi-Fi-Modi - Access Point (AP) und Client-Modus (CM).
Für den Betrieb im Client-Modus muss sich ein WLAN-Router in
Reichweite des Geräts benden. Shelly®-Geräte können über das
HTTP/HTTPS
-Protokoll direkt mit anderen Wi-Fi-Geräten kommu-
nizieren. Eine API kann vom Hersteller bereitgestellt werden.
Shelly®-Geräte können auch dann zur Überwachung und Steuerung
verfügbar sein, wenn sich der Benutzer außerhalb der Reichweite
des lokalen Wi-Fi-Netzwerks bendet, solange der Wi-Fi-Router mit
dem Internet verbunden ist. Die Cloud-Funktion könnte verwendet
werden, die über den Webserver des Geräts oder über die Einstel-
lungen in der Shelly Cloud-Mobilanwendung aktiviert wird.
Der Benutzer kann sich registrieren und auf Shelly Cloud zugreifen,
entweder über mobile Android- oder iOS-Anwendungen oder einen
beliebigen Internetbrowser und die Website:
https://my.Shelly.cloud/
Steuern Sie Ihr Zuhause mit Ihrer Stimme
Shelly®-Geräte sind mit den von Amazon Echo und Google Home
unterstützten Funktionen kompatibel. Bitte lesen Sie unsere
Schritt-für-Schritt-Anleitung auf:
https://shelly.cloud/support/compatibility/
Shelly® Pro-Serie
Die Shelly® Pro-Serie ist eine Reihe von Geräten, die für Wohnun-
gen, Büros, Einzelhandelsgeschäfte, Produktionsstätten und ande-
re Gebäude geeignet sind. Shelly® Pro-Geräte sind DIN-montierbar
im Unterbrecherkasten und sehr gut geeignet für den Neubau. Die
Konnektivität für alle Shelly® Pro-Geräte kann über eine Wi-Fi- oder
LAN-Internetverbindung erfolgen, und Bluetooth kann für den Auf-
nahmeprozess verwendet werden.
INSTALLATIONSANLEITUNG
Shelly Pro 2 Relaisschalter (2 Kanäle)
Das Shelly Pro 2 Smart Relay von Allterco Robotics soll in eine
Standard-Schalttafel auf einer DIN-Schiene neben den Leistungs
-
schaltern montiert werden, um die elektrische Leistung zu steuern
und zu überwachen. Shelly kann als eigenständiges Gerät oder
als Zubehör für eine Heimautomatisierungssteuerung verwendet
werden.
Schließen Sie das Relais an das Stromnetz an und installieren Sie es
in der Schalttafel wie im Schema (Abb. 1-6) gezeigt und befolgen
Sie die Sicherheitshinweise. Stellen Sie vor der Installation/Montage
des Geräts sicher, dass das Netz ausgeschaltet ist (ausgeschaltete
Leistungsschalter) und den Sicherheitsnormen entspricht.
Überprüfen Sie vor dem Start, ob die Leistungsschalter ausge-
schaltet sind und an ihren Klemmen keine Spannung anliegt. Dies
kann mit einem Phasenmesser oder Multimeter erfolgen. Wenn Sie
sicher sind, dass keine Spannung anliegt, können Sie mit der Ver-
drahtung der Kabel gemäß Abb. 1-6 beginnen.
Installieren Sie einen Draht von O1, O2 - zur Last und von der Last
zum Neutralleiter. Installieren Sie auch ein Kabel von der Sicherung
zu L1, L2. (Es gibt zusätzliche Pins L und N für die Stromversor-
gung des Geräts + zusätzlicher Pin für 12V DC)
Verbinden Sie den Neutralleiter mit dem Gerät. Der letzte Schritt
besteht darin, Kabel von den Schaltern zu den Klemmen SW1, SW2
zu installieren.
Bei induktiven Geräten, die beim Einschalten Spannungsspitzen
verursachen: Elektromotoren, wie Lüfter, Staubsauger und ähnli-
I2 terminal to the other second DC load circuit power supply
wire.
CAUTION The DC load circuits voltage should not exceed 30
V and the current should not exceed 12 A.
Two different voltages can be used for the two DC load circuits.
If you are using 12 V DC to power the Device, but want to switch
two AC load circuits (g. 4), connect the positive wire to the +12
terminal and the negative wire to the L terminal.
Connect the two switch circuits to the S1 and S2 input terminals
and the negative wire.
Connect the rst load circuit to the O1 terminal and the Neutral
wire. Connect the I1 terminal to the rst load circuit breaker.
Connect the second load circuit to the O2 terminal and the
Neutral wire. Connect the I2 terminal to the second load circuit
breaker.
Two different phases can be used for the two load circuits.
If you are using 12 V DC to power the Device and switch mixed
DC and AC load circuits (g.5), connect the Device power sup-
ply positive wire to the +12 terminal and the Device power sup-
ply negative wire to the L terminal. Connect the 2 switch circuits
to the S1 and S2 input terminals and the Device power supply
negative wire.
Connect the DC load circuit to the O1 terminal and one of the DC
load circuit power supply wires. Connect the I1 terminal to the
other DC load circuit power supply wire.
CAUTION The DC load circuit voltage should not exceed 30 V
and the current should not exceed 12 A.
Connect the AC load circuit to the O2 terminal and the Neutral
wire. Connect the I2 terminal to the AC load circuit breaker.
Two different voltages can be used for the DC load circuits and
for the Device power supply circuit.
If you are using 12 V DC to power the Device and switch two DC
load circuits (g.6), connect the Device power supply positive
wire to the +12 terminal and the Device power supply negative
wire to the L terminal. Connect the 2 switch circuits to the S1
and S2 input terminals and the Device power supply negative
wire.
Connect the rst DC load circuit to the O1 terminal and one of
the rst DC load circuit power supply wires. Connect the I1 ter-
minal to the other rst DC load circuit power supply wire.
Connect the second DC load circuit to the O2 terminal and one
of the second DC load circuit power supply wires. Connect the
I2 terminal to the other second DC load circuit power supply
wire.
CAUTION The DC load circuits voltage should not exceed 30
V and the current should not exceed 12 A. Two different voltages
can be used for the two DC load circuits.
RECOMMENDATION For inductive loads, which cause volt-
age spikes during switching, such as electrical motors, fans, vac-
uum cleaners, refrigerators and similar ones, RC snubber (0.1µF
/ 100Ω / 1/2W / 600V AC) should be wired in parallel with the
load. RC snubbers can purchased at
shop.shelly.cloud/rc-snubber-wi-smart-home-automation
Initial Inclusion
You can choose to use Shelly® with the Shelly Cloud mobile
application and Shelly Cloud service. Instructions on how to
connect your device to the Cloud and control it through the
Shelly App can be found in the “App Guide” included in the box.
You can also familiarize yourself with the instructions for Man-
agement and Control through the embedded Web interface at
192.168.33.1 in the Wi-Fi network, created by the Device.
CAUTION! Do not allow children to play with the button/
switch connected to the Device. Keep the Devices for remote
control of Shelly (mobile phones, tablets, PCs) away from chil-
dren.
Specications
Mounting - DIN rail
Dimensions (HxWxL): 68.5x18.5x89.5 mm
Power supply: 110 - 240 V, 50/60 Hz AC
12V DC (10.5 V - 13.5 V), 250 mA
Electrical consumption: < 3 W
Working temperature: 0 °C - 40 °C
Controlling elements: 2 galvanically isolated relays
Controlled elements: 2 circuits - 2 AC, 2 DC or mixed (1 AC
and 1 DC)
Max switching voltage: 240 V AC / 30 V DC
Max current per channel: 16 A AC / 12 A DC)
Total max. current of all outputs: 25 A
Dry contacts: Yes
Temperature Protection - YES
Wi-Fi - YES
Bluetooth - YES
LAN - YES
Scripting (mjs) - YES
MQTT - YES
CoAP - No
URL Actions - 20
Scheduling - 50
Add-on support - YES
CPU - ESP32
Flash - 8MB
Radio protocol: Wi-Fi 802.11 b/g/n
Radio signal power: 1mW
Frequency Wi-Fi : 2412-2472 МHz; (Max. 2495 MHz)
RF output Wi-Fi: <20 dBm
Operational range: (depending on terrain and building struc-
ture): up to 50 m outdoors, up to 30 m indoors
Frequency Bluetooth: TX/RX: 2402- 2480 MHz (Max.
2483.5MHz)
RF output Bluetooth: <10 dBm
Led indicators
Power (red): Red light indicator will be on if power is connected.
Wi-Fi (blue): Blue light indicator will be on if the Device is in AP
mode.
Wi-Fi (red): Red light indicator will be on if the Device is in STA
mode and not connected to a local Wi-Fi network.
Wi-Fi (yellow): Yellow light indicator will be on if the Device is in
STA mode and connected to a local Wi-Fi network. Not connect-
ed to Shelly Cloud or Shelly Cloud disabled.
Wi-Fi (green): Green light indicator will be on if the Device is in
STA mode and connected to a local Wi-Fi network and to the
Shelly Cloud.
Wi-Fi (ashing): The light indicator will be ashing Red/Blue if
OTA update is in progress.
LAN (green): Green light indicator will be on if LAN is connect-
ed.
Out1 (red): Red light indicator will be on if the Output 1 rellay
is closed.
Out2 (red): Red light indicator will be on if the Output 2 rellay
is closed.
Declaration of conformity
Hereby, Allterco Robotics EOOD declares that the radio equip-
ment type Shelly Pro 2 is in compliance with Directive 2014/53/
EU, 2014/35/EU, 2014/30/EU, 2011/65/EU. The full text of the
EU declaration of conformity is available at the following inter-
net address
https://shelly.cloud/knowledge-base/devices/shelly-pro-2/
Manufacturer: Allterco Robotics EOOD
Address: Bulgaria, Soa, 1407, 103 Cherni vrah Blvd.
Tel.: +359 2 988 7435
E-mail: support@shelly.cloud
Web: http://www.shelly.cloud
Changes in the contact data are published by the Manufactur-
er at the ocial website of the Device http://www.shelly.cloud
All rights to trademark Shelly® and other intellectual rights
associated with this Device belong to Allterco Robotics EOOD.
ches, RC-Snubber (0,1µF / 100Ω / 1/2W / 600V AC) zwischen Aus-
gang und Neutralleiter des Stromkreises verdrahten .
ACHTUNG! Installieren Sie das Gerät nicht an einem Ort, der nass
werden kann.
ACHTUNG! Stromschlaggefahr. Die Montage/Installation des
Geräts an das Stromnetz muss mit Vorsicht von einer qualizierten
Person (Elektriker) durchgeführt werden.
ACHTUNG! Gefahr eines Stromschlags. Die Montage des Geräts
an das Stromnetz muss mit Vorsicht erfolgen.
ACHTUNG! Erlauben Sie Kindern nicht, mit dem an das Gerät an-
geschlossenen Knopf/Schalter zu spielen. Halten Sie die Geräte zur
Fernsteuerung von Shelly (Mobiltelefone, Tablets, PCs) von Kindern
fern.
ACHTUNG! Stromschlaggefahr. Auch wenn das Gerät ausge-
schaltet ist, kann an seinen Klemmen Spannung anliegen. Jede Än-
derung des Anschlusses der Terminals muss durchgeführt werden,
nachdem sichergestellt wurde, dass die gesamte lokale Stromver-
sorgung ausgeschaltet/getrennt ist.
ACHTUNG! Schließen Sie das Gerät nicht an Geräte an, die die
angegebene maximale Last überschreiten!
ACHTUNG! Verwenden Sie das Gerät nur mit einem Stromnetz
und Geräten, die allen geltenden Vorschriften entsprechen. Ein Kurz-
schluss im Stromnetz oder an dem Gerät angeschlossenen Geräten
kann das Gerät beschädigen.
ACHTUNG! Schließen Sie das Gerät nur auf die in dieser Anlei-
tung gezeigte Weise an. Jede andere Methode kann zu Schäden
und/oder Verletzungen führen.
ACHTUNG! Das Gerät darf nur an Stromkreise und Geräte an-
geschlossen werden und diese steuern, wenn diese den jeweiligen
Normen und Sicherheitsnormen entsprechen.
ACHTUNG! Das Gerät kann mit massiven einadrigen Kabeln mit
erhöhter Wärmebeständigkeit bis zur Isolierung von mindestens
PVC T105°C angeschlossen werden.
Erstaufnahme
Sie können wählen, ob Sie Shelly mit der mobilen Shelly Cloud-An-
wendung und dem Shelly Cloud-Dienst verwenden chten. Eine
Anleitung, wie Sie Ihr Gerät mit der Cloud verbinden und über die
Shelly App steuern, nden Sie in der „App-Anleitung“. Sie können
sich auch über die eingebettete Webschnittstelle mit den Anwei-
sungen für Management und Kontrolle vertraut machen.
Spezikation
Stromversorgung: 110-240V; 50/60Hz Wechselstrom;
12V DC
(Gleichstrombereich: + 10.5V ÷ 13.5V; 250mA)
Max. Strom pro Kanal: 16 A
Gesamt max. Strom aller Ausgänge: 25 A
DC Ausgang: 0 ÷ 30V; 12A
Umgebungstemperatur: 0°C - 40°C
Funksignalleistung: 1mW
Funkprotokoll: Wi-Fi 802.11 b/g/n
Frequenz: 2412-2472 МHz; (Max. 2483,5 MHz)
Einsatzbereich (je nach örtlicher Bebauung):
- bis 50 m im Freien,
- bis 30 m im Innenbereich
Abmessungen (HxBxL):
68,5x18,5x89,5
mm
Stromverbrauch: < 3 W
Spezikation Größe und Abmessungen
Montage - DIN-Schiene
WLAN - JA
Bluetooth - JA
LAN - JA
Temperaturschutz - JA
Skripting (mjs) - JA
MQTT - JA
CoAP - Nein
URL-Aktionen - 20
Terminplanung - 50
Add-on-Unterstützung - JA
CPU - ESP32
Flash - 8 MB
LED INDICATORS
Power (rot): Die rote Leuchtanzeige leuchtet, wenn die Strom-
versorgung angeschlossen ist.
Wi-Fi (blau): Die blaue Lichtanzeige leuchtet, wenn Wi-Fi ver-
bunden ist.
LAN (grün): Grüne Lichtanzeige leuchtet, wenn LAN verbun-
den ist.
Ausgang 1 (rot): Die rote Leuchtanzeige leuchtet, wenn der
Ausgang 1 angeschlossen ist.
Ausgang 2 (rot): Die rote Leuchtanzeige leuchtet, wenn der
Ausgang 2 angeschlossen ist.
TECHNISCHE INFORMATION
Steuerung über Wi-Fi von einem Mobiltelefon, PC, Automatisie-
rungssystem oder einem anderen Gerät, das das HTTP- und/oder
UDP-Protokoll unterstützt.
Mikroprozessorverwaltung.
Kontrollierte Elemente: 2 Stromkreise/ Geräte.
Bedienelemente: 2 Relais.
Shelly kann über einen externen Taster/Schalter gesteuert wer-
den.
KONFORMITÄTSERKLÄRUNG
Hiermit erklärt Allterco Robotics EOOD, dass der Funkanlagentyp
Shelly Pro 2 der Richtlinie 2014/53/EU, 2014/35/EU, 2014/30/EU,
2011/65/EU entspricht. Den vollständigen Text der EU-Konformi-
tätserklärung nden Sie unter folgender Internetadresse
https://shelly.cloud/knowledge-base/devices/shelly-pro-2/
Hersteller: Allterco Robotics EOOD
Adresse: Bulgarien, Soa, 1407, 103 Cherni vrah Blvd.
Tel.: +359 2 988 7435
E-Mail: support@shelly.cloud
Internet: http://www.shelly.cloud
Änderungen der Kontaktdaten werden vom Hersteller auf der o-
ziellen Website des Geräts veröffentlicht
http://www.shelly.cloud
Alle Rechte an der Marke Shelly® und anderen geistigen Eigen-
tumsrechten im Zusammenhang mit diesem Gerät gehören Allter-
co Robotics EOOD.
89,5 mm
68,5 mm
18,5 mm
Power
Wi-Fi
LAN
Out 1
Out 2
Reset
O1 I1
O2 I2
L N +12
SW1 SW2
LAN
L1(A)
L2(B)
L3(C)
N
Power
Wi-Fi
LAN
Out 1
Out 2
Reset
O1 I1
O2 I2
L N +12
SW1 SW2
LAN
L1(A)
L2(B)
N
DC
≤30 V
Power
Wi-Fi
LAN
Out 1
Out 2
Reset
O1 I1
O2 I2
L N +12
SW1 SW2
LAN
L
DC
≤30 VDC
≤30 V
N
-
DC
12 V
+
Power
Wi-Fi
LAN
Out 1
Out 2
Reset
O1 I1
O2 I2
L N +12
SW1 SW2
LAN
L1(A)
L2(B)
N
-
DC
12 V
+
Power
Wi-Fi
LAN
Out 1
Out 2
Reset
O1 I1
O2 I2
L N +12
SW1 SW2
LAN
L
N
DC
≤30 V
-
DC
12 V
+
Power
Wi-Fi
LAN
Out 1
Out 2
Reset
O1 I1
O2 I2
L N +12
SW1 SW2
LAN
DC
≤30 VDC
≤30 V
g.1
g.3
g.5g.2
g.4
g.6

Summary of content (1 pages)