PROBLEM Bugsfoundinwood.
POSSIBLECAUSE Woodhasrottedorhasbeenlayingaroundforanextendedperiodoftime.
REMEDY
Inspectthewoodforobvioussignsofinsectinfestationsuchasburrowsorholes,
avoidusingifpossible.Donotstorewoodindoors.
PROBLEM
Draftblowerwillnotrun.NOTE:Verifythatthewallthermostatisinthe"HEAT"
position,andmakesurebatteriesareinstalled.
POSSIBLECAUSE Defectiverockerswitchoncontrolcenter.
REMEDY Replacerockerswitch.
POSSIBLECAUSE Defectivewallthermostat.
REMEDY
Thiscanbecheckedbyturningthethermostattoatemperaturesettingthatishigher
thanthetemperatureinyourhome.Ifthedraftblowerdoesnotoperate,the
thermostatmaybedefective.Replaceifnecessary.
POSSIBLECAUSE Wallthermostatisinthewrongposition.
REMEDY Moveswitchonwallthermostattothe"HEAT"position.
POSSIBLECAUSE Defectiverelayintransformer.
REMEDY Replacerelay.
POSSIBLECAUSE Defectivedraftmotor.
REMEDY Replacedraftmotor.
POSSIBLECAUSE Improperwiring.
REMEDY
Reviewwiringdiagram.Ifwiredcorrectly,seekprofessionalassistance.
PROBLEM Draftblowerrunsconstantly.
POSSIBLECAUSE Defectivewallthermostat.
REMEDY
Thiscanbecheckedbyturningthethermostattoalowersettingthanthetemperature
inyourhome.Ifthedraftblowercontinuestorun,thethermostatmaybedefective.
Replaceifnecessary.
POSSIBLECAUSE Defectiverelayintransformer.
REMEDY Replacetransformerandrelay.
POSSIBLECAUSE
Homeisnotbeingsuppliedwithasufficientamountofheattosatisfythewall
thermostat.
REMEDY
Haveaprofessionaldeterminethepropersizefurnaceandinsulationfactorofyour
home.
1
2
3
PROBLEM Odordetectedinhomeduringinitialfiring.
POSSIBLECAUSE
Thereisanoilyfilmthatremainsonthesteelafterthemanufacturingprocess.Firing
thefurnacehasraisedthetemperatureofthefireboxtoalevelthatissufficientto
vaporizetheresidue.
REMEDY
Thisodorshoulddisappearafterafewhoursofusage.
PROBLEM Smokefromthefirechamberispuffingbackthroughtheforceddraftmotor.
POSSIBLECAUSE Furnaceisnotconnectedtoreturnairandisdrawingsmokefumesfromtheflue.
REMEDY
Connecttoreturnairductsystem.Orroommaybetooairtight,referto"Locationand
Installation"sectiononpage3.
POSSIBLECAUSE Excessivelylongrunofstovepipefromfurnacetoflue
REMEDY
Relocatethefurnacesothehorizontalrundoesnotexceed5feetandhasa2inchrise
perfoot.
POSSIBLECAUSE Toomanyelbows.
REMEDY Therunshouldnotcontainmorethan2elbows.
POSSIBLECAUSE Insufficientfluesize.
REMEDY
Replacewithalargerflueprovidingaminimumof50squareinchesbutnotmorethan
100squareinchesofdraftarea.Iftheflueiswithinthesespecifications,checkthe
draftwithadraftgage(manometer).Yourflueshouldprovideaminimumof.04
watercolumninchesandamaximumof.08watercolumninches.
8
7
PROBLEM Flamesdischargingfromfueldoorduringreloading.
POSSIBLECAUSE
Openingthedoorhasprovidedadditionaloxygenwhichhasignitedtheaccumulated
gasesfrompartiallyspentfuel.
REMEDY
Alwaysopenthedoorcautiouslyandallowthesafetylatchsystemtoperformits
designedfunction,containinggaseswithinthefirechamber.
POSSIBLECAUSE Bypassrodisin"CLOSED"position.
REMEDY Pulloutbypassrod.
POSSIBLECAUSE
Castirondamperinthe"CLOSED"position
REMEDY Opendamper.
POSSIBLECAUSE Insufficientnaturaldraftoranobstructioninthefluesystem.
REMEDY See#6and#9
POSSIBLECAUSE Firechamberfilledtocapacitywithunburnedfuel.
REMEDY
Donotattempttooverloadthefurnace.
PROBLEM Excessivedirtaccumulationsurroundingairregistersinthehome.
POSSIBLECAUSE Smokedischargefromloadingdoorwhilerefueling.
REMEDY Alwayspullexhaustbypassrodcompletelyforwardbeforeopeningfueldoor.
POSSIBLECAUSE
Furnaceisnotconnectedtoreturnairductandisdrawingdirtfromfurnaceroomfloor
anddisbursingitthroughoutthehome.
REMEDY Connecttoreturnairductsystem.
POSSIBLECAUSE Filterboxnotinstalled,ornofilterinfilterbox.
REMEDY
Installfilterboxonfurnace.Installfilterinfilterbox.