Specifications

DX-BT24-S MODULE SPECIFICATION
Shenzhen DX-SMART Technology Co., Ltd. www.szdx-smart.com
- 19 -
Table 10:Working voltage table
Operating Voltage
parameter Minimum Typical Max unit
V
IN
- Core supply voltage(VDD) 2.8 3.3 3.6 V
V
IN
- I/O power supply/voltage(VDDIO 2.8 3.3 3.6 V
3.2. Working And Storage Temperature
Table 11:Working and storage temperature table
parameter Minimum Typical Max unit
Normal working temperature -40 - 85 ºC
storage temperature -50 - 150 ºC
3.3. Power Consumption
Table 12:Power consumption table
mode state Current Unit
Hibernation mode - 2 uA
Low power mode
not connected 19 uA
connected 341 uA
Normal working
mode
not connected 270 uA
connected 341 uA
When transparently
transmitting data
connected
MIN:341uA
MAX:986uA
MIN is the power consumption
when not sending data
MAX is the power consumption
when the data volume sent by the
module is 10626bytes/s
Remark
The power consumption in the above table is measured at a broadcast interval of 540ms, for
reference only. The power consumption of this module in different broadcast intervals is
different, the specific power consumption is subject to the actual.