User's Manual

E Training/Simulator
F STICK setting
G Stick calibration
Menu display: TRSI 18 (Helicopter mode) NOR / TRA / SIMU
Function: Training / Simulator Normal/Training mode / Simulator mode
Function description:
1 NOR: Normal mode, RF 2.4Ghz working normally, can not work as a trainer but can be work as a trainee.
2 TRA: when this transmitter work as
a trainer, the other transmitter work as a trainee through a training
cable. Using together with the training switch, the trainer is active when the switch disabled, when the
training switch is working, the trainee will be the activate transmitter.
3 SIMU: the RF2.4G will be shut off in order for connect with other transmitter or connect to the computer for
simulation training. Shutting the RF off will significantly increase the battery life.
Setting method:
1, press and hold Menu button to enter TRSI, displayed as TRSI 18
2, When NOR/TRA/SIMU being displayed, press UP/DOWN to switch to the mode you need
3, Press and hold + button to confirm and save, press any other button to cancel the setting.
Menu display: STK 19 (Helicopter mode) - 1,2,3,4
Function: Stick setting Mode1 mode2 mode 3 mode 4
Function description: Stick setting will let the user to set the stick according to their
habit. There are 4
different modes for option. If the transmitter has preset mode, please do not change by your own.
Setting method:
1, press menu to enter STK, display STK19
2, Press UP/DOWN to switch to the mode you need
3, Press and hold + button to confirm and save the
setting, press any other keys to cancel the setting.
Menu display: CALI 20 (helicopter mode) CENT /LOW/ HIGH /OK/ERR
Function: Stick Calibration- center position/ low position/ high position/ OK/ Error
Function description: Stick calibration can be used to calibrate the stick after changing the stick mode.
Setting method:
1, press
menu to enter CALI, displayed CALI 20 for 1 second, and then CENT will be shown
2, press +/- button to switch to the channel need to be calibrated, e.g. CH1
3, when CENT displayed, Put the corresponding stick to the Center position, press Down button to confirm
and enter to the
LOW Calibration, Push the stick to the left (Throttle and elevator to the bottom, Aileron and
rudder to the left side) Press down button to confirm and enter the HIGH calibration (Throttle and elevator to
the top, Aileron and rudder to the right side), press down button again, OK being displayed means the
calibration was successfully completed, if ERR being displayed, it means the calibration was fail and please
redo the process again.
4, repeat the process of step 2, 3 to complete the calibration for other channels.
5, The value will be displayed as -100% when the stick push to the
bottom, displayed 0% on the center,
displayed as +100% when pushed to the top.
6,press menu button to save and exit after calibration successfully completed.
Basic opera tion
Initial setup
12
1--Aileron
2--Elevator
3--Throttle
4--Rudder
Mode 1 Mode 2 Mode 3 Mode 4