Specifications

Ra-01SC Specification V1.1
2. Electrical parameters
Ra-01SC series modules are electrostatic sensitive devices, special precautions need to be taken when
handling.
Note
Ra-01SC module is electrostatic sensitive devices
ESD
),
It requires special ESD precautions and should
generally be classified as an ESD sensitive component. During the entire handling, transportation and
operation of the Ra-01SC module, proper ESD handling and packaging procedures should be used. Please do
not touch the module with hands or use a non-antistatic soldering iron for soldering, so as not to damage
the module.
2.1. Electrical character
Parameter Name Min Typ Max Unit Remarks
Operating
temperature
TOPR -40 25 85
Industrial design
Supply
voltage
VDD 2.7 3.3 3.6 V
≥3.3V(Guaranteed
output power)
2.2. Digital port characteristics
Description Typ Unit
Operating frequency
410~525 MHz
IO Name Min Typ Max Unit
IO level
VIO 2.7 3.3 3.6 V
Low input logic
level
VIL - - 0.2 V
High input logic
level
VIH 0.8 - - V
Copyright © 2021 Shenzhen Ai-Thinker Technology Co., Ltd All Rights Reserved
Page 7 of 19