Wiring Diagram

Haisen Technology | 03
Shenzhen Haisen Technology Co., Ltd., Tel: +86-755-82598105 Fax: +86-755-82598106Email: info@haisensz.com www.haisensz.com
Installation Method
With insufficient
daylight, when motion
detected, light ON.
With sufficient daylight,
even when motion
detected, light remains
OFF.
After the stand-by
period, light OFF.
After last detection, the
light will be dimmed
down to the stand-by
dimming level
(10%,20%,30% or 50%)
after holdtime.
Hold time
Stand-by period
3. Function Demo - Dimmable control/Corridor function
Hold time
After the last detection and
the present hold time
elapsed, light OFF.
With sufficient daylight,
even when motion detected,
light remains OFF.
With insufficient daylight,
when motion detected, light
ON.
After people leave the detection
area, light remains 100%
brightness within hold time.
When motion is detected,
the sensor will switch on the
light to 100% brighteness.
After the last detection and
the present hold time
elapsed, light OFF.
1. Automatically ON/OFF function:
Light on when detect movement and off after people leave at night. Applications: Corridor, Staircase.
1
2
1
2
3
2. No daylight function
The daylight threshold is set to "Disable".
Light on when detect movement, After people leave, Light off
after stand-by period
.
Applications: Dim places such as Basement Parking, Underpass.