H2 air cleaner
1. Important safety information Before using this product, please read this user manual carefully and keep it for future reference. DANGER · do not use water or any other liquid or flammable detergent to clean the product, so as to avoid electric shock or fire. · do not use water or any other liquid or (flammable) detergent to clean the product to avoid electric shock or fire.
· do not place the product directly under the air conditioner to prevent condensate dripping into the product. · before turning on the power supply of the product, make sure that all filter elements have been correctly installed and the packaging bag has been removed. · only use the original filter element specially designed by our company, and do not use any other filter element. Do not knock the product with hard objects (especially the air inlet and outlet).
Model: H2 Size: 187 * 187 * 300mm Weight: 1.83kg Control mode: touch button Color: white Essence Technology: High efficiency filter with coconut shell activated carbon 2.12 billion non-equilibrium ion sterilization and deodorization technology Trial area: ≤ 25 m2 grain: CADR:80 M2 / h formaldehyde: CADR:40 M2 / h noise: ≤ 45dB Power: 12V 3A 8W - 36W 3. Getting Started Install the filter element High efficiency composite filter element is attached to the air cleaner.
3.1 take out the filter element 3.2 Then remove the packaging from the filter element 3.3 Install the filter element back into the purifier, then push the bottom cover into the fuselage and rotate the bottom cover and lock it tightly. 4. Using air cleaner 4.
4.2 understand the warning indicator of filter element replacement This product is equipped with a high efficiency composite filter element assembly. When PM2.5 displays flashing, it means that the filter element needs to be cleaned or replaced. 4.3 wind speed regulation You can choose the required wind speed. The wind speed is low by default. 4.4 press the switch button to turn on the purifier. 4.
In standby mode, press and hold the UV key for 5 seconds to enter the forced filter element replacement mode, and the PM2.5 display bit flashes. At this time, press and hold the UV key for 5 seconds to clear the filter element, and the filter element will be timed again from zero. The PM2.5 display is normal. If there is no operation within 60 seconds, the mode will exit automatically, and the on-off key and the negative ion key indicator will be off. 4.13 PM2.
5.2.1 stabilize the machine, then rotate 20 degrees from the handle of the air inlet net according to the unlocking direction of the arrow, and then pull out the air inlet net. 5.2.2 grasp the tab and pull the filter element out of the machine. 5.2.3 remove the packing material from the new filter element. 5.3 Install the filter element back into the purifier body.
· install the filter in the correct position. · push the air inlet net under the fuselage and rotate the air inlet net. When you hear a "click", the assembly is completed. · reset the filter life timer, PM2.5 display bar flashes, long press UV key for 5 seconds, if PM2.5 display is normal, the time timer will clear. ————Fault types and treatment methods———— 6. Fault types and treatment methods This chapter summarizes the most common problems you encounter when using the purifier.
no optimal purification capacity The The air inlet or outlet of the machine is blocked screen Please remove the foreign matter from the air inlet Please plug in the product, press change and hold the switch button, and indicator keeps The filter reset button was not then press the filter reset button flashing after pressed correctly for 3 seconds the filter is replaced 7. Design criteria: The design of the product must meet at least the following standards: GB / t18801-2015 air cleaner Gb4706.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.